    User name a-onl

    Log entry time 19:18:40 on May 9, 2002

    Entry number 3035

    keyword=Start_Run_1407,Run_type=production,beam_energy=5.562,beam_raster=off,comment_text=71 microamps beam -raster off - Q^2 = 4.1 Pointing Run,daq_mode=Unbuff,leftarm_p=+2.979,leftarm_theta=30.998,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=+0.756,rightarm_theta=65.663,target_name=Thin Carbon,target_type=Carbon (thin)
    Beginning-of-run EPICS data for Run Number 1407 at Thu May 9 19:18:29 EDT 2002
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ; PS1 for the Right spectrometer based on T1 defined by S1*S2
    ; PS2 for the Right spectrometer based on T2 defined by S1+S2
    ; PS3 for the Left spectrometer based on T3 defined by S1*S2
    ; PS4 for the Left spectrometer redundant trigger T4 S1*S0+S2*S0
    ; PS5 for coincidence of T1 and T3.
    ; PS7 irrelevant
    ; PS8 for pulser 
    ps1=60,ps2=200,ps3=1,ps4=2,ps5=1,ps6=65535,ps7=65535,ps8=65535
     
    Left Arm Q1 power supply current : 2241.44
    Left Arm Q1 momentum : 2.97932
    Left Arm Q1 gauss meter : 0.18993
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1283.01
    Left Arm Q2 momentum : 2.9796
    Left Arm Q2 gauss meter : -0.6751
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1042.44
    Left Arm D1 momentum : 2.979
    Left Arm D1 NMR : 1.10305
    Left Arm Q3 power supply current : 1186.03
    Left Arm Q3 momentum : 2.97908
    Left Arm Q3 gauss meter : 0.5935
    Left Arm Q3 power supply polarity : 0
    Right Arm Q1 power supply current : 568.435
    Right Arm Q1 momentum : 0.755963
    Right Arm Q1 gauss meter : 0.01428
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 325.373
    Right Arm Q2 momentum : 0.756035
    Right Arm Q2 gauss meter : -0.17205
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 260.74
    Right Arm D1 momentum : 0.755998
    Right Arm D1 NMR : 0.280542
    Right Arm Q3 power supply current : 300.755
    Right Arm Q3 momentum : 0.755839
    Right Arm Q3 gauss meter : -0.13531
    Right Arm Q3 power supply polarity : enabled
    Left Arm Top VDC Current : 4.29688
    Left Arm Bottom VDC Current : 3.27148
    Right Arm Top VDC Current :
    Right Arm Bottom VDC Current :
    Average current of the two cavities : 0.0309816
    Current on Unser monitor : 4.17666
    Current on Upstream bcm : 0.0359227
    Current on Downstream bcm : 0.0260404
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    Tiefenbach Hall A energy : 5554.5
    Tiefenbach Hall C energy : 5566
    Delta(E)/E width (MV_AI_DXWID) : 0.628918
    MBSY1c Hall A Beam energy : 5566.04
    MBSY3c Hall C Beam energy : 5582.95
    MBSY1c magnet current (amp) : 232.601
    MBSY1c Bdl : 1.38901e+06
    Arc1 dp/p : 0.000121044
    Arc2 dp/p : -0.00146581
    Left Arm Arm Collimator : 0.615479
    Left LVDT HPM : -639
    Left LVDT VPM : 6
    HacL_HPE1313A:0_Ch58 : -0.154785
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : -0.222168
    HacL_alignROLL : 0.135976
    HacL_alignPITCH : -0.105732
    HacL_alignHPT : -0
    Left Arm Angle Floor Angle : 31
    Left Arm Angle Vernier : 30.3
    Left Arm Scattering Angle : 30.9956
    Right Arm Arm Collimator : 0.612061
    Right LVDT HPM : 389
    Right LVDT VPM : 808
    HacR_HPE1313A:0_Ch58 : -0.508301
    HacR_HPE1313A:0_Ch55 : 21.6309
    HacR_HPE1313A:0_Ch54 : -0.805176
    HacR_alignROLL : 0.466989
    HacR_alignPITCH : -0.489172
    HacR_alignHPT : -0
    Right Arm Angle Floor Angle : 65.5
    Right Arm Angle Vernier : -5.9
    Right Arm Scattering Angle : 65.663
    IPM1C12.XPOS : 0
    IPM1C12.YPOS : 0
    IPM1H04A.XPOS : 0.00508954
    IPM1H04A.YPOS : 0.00212666
    IPM1H04B.XPOS : -0.00912368
    IPM1H04B.YPOS : 0.0480443
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle : 12.4959
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 307.42
    Wien field : 8.2213
    Laser attenuation Hall A : 100
    Laser power Hall A : 60
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -5.5589
    Target OTR y-position : 7.08516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : Current is Low
    Arc OTR x-position : -1.20989
    Arc OTR y-position : -0.32064
    Arc OTR x-width : 2.94949
    Arc OTR y-width : 2.97435
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0