• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 22:24:33 on May 9, 2002

    Entry number 3050

    keyword=End_of_Run_1413
    ****************************
     Run Number: 1413
     End of Run Comment:
    Run_type=production,beam_energy=5.562,beam_raster=on,comment_text=71 microamps beam - raster on - Q^2 = 4.1 LH2 Production Run,daq_mode=Unbuff,leftarm_p=+2.979,leftarm_theta=30.998,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=+0.756,rightarm_theta=65.663,target_name=4cm LH2,target_type=4cm Hydrogen
     
    
    PRESCALE FACTORS:ps1=90   ps2=200   ps3=1   ps4=2   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS[0]: 49052        [+]: 24090        [-]: 24012        
    TIME  [0]: 5.859 mins  [+]: 2.871 mins  [-]: 2.871 mins  
    LIVE  [0]:  92.28%      [+]:  92.39%      [-]:  92.29%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :67.7/6088.8 Hz   T2[0] :19.6/3930.4 Hz   T3[0] :40.8/40.8 Hz   T4[0] :19.9/39.8 Hz   T5[0] : 3.2/3.2  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :67.6/6088.1 Hz   T2[+] :19.7/3931.3 Hz   T3[+] :40.8/40.8 Hz   T4[+] :20.0/40.1 Hz   T5[+] : 3.2/3.2  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :67.7/6092.2 Hz   T2[-] :19.7/3930.8 Hz   T3[-] :40.9/40.9 Hz   T4[-] :19.8/39.5 Hz   T5[-] : 3.1/3.1  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :  23784/2140602  T2[0] :   6908/1381794  T3[0] :  14358/14358    T4[0] :   6994/13989    T5[0] :   1108/1108     T8[0] :      5/360003   
    T1[+] :  11651/1048634  T2[+] :   3385/677136   T3[+] :   7029/7029     T4[+] :   3451/6903     T5[+] :    556/556      T8[+] :      2/176377   
    T1[-] :  11660/1049439  T2[-] :   3385/677109   T3[-] :   7038/7038     T4[-] :   3403/6806     T5[-] :    530/530      T8[-] :      2/176393   
    
    AVERAGE CURRENT
    BCM x1 : 16.1858uA  BCM x3 : 16.2191uA  BCM x10: 14.6557uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -525.3 ppm     BCM u3 :   -540.8 ppm     BCM u10:   -541.2 ppm     
    BCM d1 :   -519.9 ppm     BCM d3 :   -537.4 ppm     BCM d10:   -545.5 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.005571       BCM u3 [0]:0.005586       BCM u10[0]:0.005352       
    BCM u1 [+]:0.002728       BCM u3 [+]:0.002736       BCM u10[+]:0.002621       
    BCM u1 [-]:0.002731       BCM u3 [-]:0.002739       BCM u10[-]:0.002624       
    
    BCM d1 [0]:0.00581        BCM d3 [0]:0.005819       BCM d10[0]:0.004952       
    BCM d1 [+]:0.002845       BCM d3 [+]:0.00285        BCM d10[+]:0.002425       
    BCM d1 [-]:0.002848       BCM d3 [-]:0.002853       BCM d10[-]:0.002428       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1413 at Thu May 9 22:24:22 EDT 2002
    Left Arm D1 momentum : 2.979
    Left Arm arm angle : 30.9956
    Right Arm D1 momentum : 0.755999
    Right Arm arm angle : 65.663
    Tiefenbach Hall A energy : 5554.6
    Left Arm arm mispointing (HPT) : -0
    Right Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 3.125
    Left Arm Bottom VDC Current : -2.49023
    Right Arm Top VDC Current :
    Right Arm Bottom VDC Current :
    Left Arm Q1 power supply current : 2241.44
    Left Arm Q1 momentum : 2.97932
    Left Arm Q1 gauss meter : 0.1899
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1282.69
    Left Arm Q2 momentum : 2.97885
    Left Arm Q2 gauss meter : -0.6751
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1042.42
    Left Arm D1 momentum : 2.979
    Left Arm D1 NMR : 1.10305
    Left Arm Q3 power supply current : 1186.02
    Left Arm Q3 momentum : 2.97905
    Left Arm Q3 gauss meter : 0.5935
    Left Arm Q3 power supply polarity : 0
    Right Arm Q1 power supply current : 568.435
    Right Arm Q1 momentum : 0.755963
    Right Arm Q1 gauss meter : 0.014287
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 325.385
    Right Arm Q2 momentum : 0.756064
    Right Arm Q2 gauss meter : -0.1721
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 260.732
    Right Arm D1 momentum : 0.755998
    Right Arm D1 NMR : 0.280542
    Right Arm Q3 power supply current : 300.854
    Right Arm Q3 momentum : 0.756088
    Right Arm Q3 gauss meter : -0.13533
    Right Arm Q3 power supply polarity : enabled
    Average current of the two cavities : 0.0345651
    Current on Unser monitor : 5.03074
    Current on Upstream bcm : 0.0405598
    Current on Downstream bcm : 0.0280672
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    MBSY1c Hall A Beam energy : 5566.04
    MBSY1c magnet current (amp) : 232.601
    MBSY1c Bdl : 1.38901e+06
    MBSY3c Hall C Beam energy : 5582.95
    Tiefenbach Hall A energy : 5554.6
    Tiefenbach Hall C energy : 5566
    Delta(E)/E width (MV_AI_DXWID) : 1.02613
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Collimator : 0.61543
    Left LVDT HPM : -596
    Left LVDT VPM : -10
    HacL_HPE1313A:0_Ch58 : -0.153809
    HacL_HPE1313A:0_Ch55 : 23.0469
    HacL_HPE1313A:0_Ch54 : -0.230469
    HacL_alignROLL : 0.128397
    HacL_alignPITCH : -0.106531
    HacL_alignHPT : -0
    Right Arm Collimator : 0.612061
    Right LVDT HPM : 394
    Right LVDT VPM : 765
    HacR_HPE1313A:0_Ch58 : -0.508789
    HacR_HPE1313A:0_Ch55 : 21.6797
    HacR_HPE1313A:0_Ch54 : -0.805176
    HacR_alignROLL : 0.466989
    HacR_alignPITCH : -0.489172
    HacR_alignHPT : -0
    Wien angle : 12.4959
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 307.42
    Wien field : 8.2213
    Laser attenuation Hall A : 100
    Laser power Hall A : 60
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -5.5589
    Target OTR y-position : 7.08516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : Current is Low
    Arc OTR x-position : -1.22316
    Arc OTR y-position : -0.292971
    Arc OTR x-width : 2.95149
    Arc OTR y-width : 2.97668
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0