NEXT
User name a-onl
Log entry time 06:28:41 on May 10, 2002
Entry number 3076
keyword=End_of_Run_1423
****************************
Run Number: 1423
End of Run Comment:
Run_type=production,beam_energy=5.562,beam_raster=on,comment_text=30 microamps beam - raster on - Q^2 = 4.1 dummy target Run,daq_mode=Unbuff,leftarm_p=+2.979,leftarm_theta=30.998,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=+0.756,rightarm_theta=65.663,target_name=4cm LH2,target_type=4cm Dummy
PRESCALE FACTORS:ps1=90 ps2=200 ps3=1 ps4=2 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 996278 [+]: 488703 [-]: 487972
TIME [0]: 75.316 mins [+]: 36.916 mins [-]: 36.915 mins
LIVE [0]: 94.70% [+]: 94.69% [-]: 94.71%
TRIGGER RATES: PRES/REAL
T1[0] :100.2/9015.1 Hz T2[0] :27.2/5432.2 Hz T3[0] :76.6/76.6 Hz T4[0] :25.7/51.4 Hz T5[0] : 3.1/3.1 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :100.2/9016.7 Hz T2[+] :27.2/5434.3 Hz T3[+] :76.8/76.8 Hz T4[+] :25.7/51.4 Hz T5[+] : 3.1/3.1 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :100.1/9012.5 Hz T2[-] :27.1/5429.7 Hz T3[-] :76.4/76.4 Hz T4[-] :25.7/51.4 Hz T5[-] : 3.2/3.2 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 452652/40738754 T2[0] : 122738/24547699 T3[0] : 346192/346192 T4[0] : 116177/232354 T5[0] : 14155/14155 T8[0] : 70/4627392
T1[+] : 221903/19971342 T2[+] : 60182/12036589 T3[+] : 170108/170108 T4[+] : 56973/113947 T5[+] : 6904/6904 T8[+] : 34/2268091
T1[-] : 221799/19961960 T2[-] : 60131/12026300 T3[-] : 169328/169328 T4[-] : 56925/113851 T5[-] : 6987/6987 T8[-] : 34/2268069
AVERAGE CURRENT
BCM x1 : 25.8281uA BCM x3 : 25.8967uA BCM x10: 25.8911uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 340.9 ppm BCM u3 : 324.5 ppm BCM u10: 326.5 ppm
BCM d1 : 341.3 ppm BCM d3 : 317.5 ppm BCM d10: 322 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.1142 BCM u3 [0]:0.1146 BCM u10[0]:0.1148
BCM u1 [+]:0.05597 BCM u3 [+]:0.05619 BCM u10[+]:0.05631
BCM u1 [-]:0.05593 BCM u3 [-]:0.05616 BCM u10[-]:0.05627
BCM d1 [0]:0.1193 BCM d3 [0]:0.1194 BCM d10[0]:0.1192
BCM d1 [+]:0.05848 BCM d3 [+]:0.05856 BCM d10[+]:0.05842
BCM d1 [-]:0.05844 BCM d3 [-]:0.05853 BCM d10[-]:0.05838
****************************
End-of-run EPICS data for Run Number 1423 at Fri May 10 06:28:28 EDT 2002
Left Arm D1 momentum : 2.979
Left Arm arm angle : 30.9956
Right Arm D1 momentum : 0.755999
Right Arm arm angle : 65.663
Tiefenbach Hall A energy : 5554.6
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Top VDC Current : -1.95312
Left Arm Bottom VDC Current : 1.75781
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Left Arm Q1 power supply current : 2241.33
Left Arm Q1 momentum : 2.97918
Left Arm Q1 gauss meter : 0.18992
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1282.93
Left Arm Q2 momentum : 2.9794
Left Arm Q2 gauss meter : -0.675
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1042.42
Left Arm D1 momentum : 2.979
Left Arm D1 NMR : 1.10305
Left Arm Q3 power supply current : 1185.88
Left Arm Q3 momentum : 2.97871
Left Arm Q3 gauss meter : 0.5935
Left Arm Q3 power supply polarity : 0
Right Arm Q1 power supply current : 568.505
Right Arm Q1 momentum : 0.756056
Right Arm Q1 gauss meter : 0.014286
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 325.44
Right Arm Q2 momentum : 0.756191
Right Arm Q2 gauss meter : -0.17208
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 260.732
Right Arm D1 momentum : 0.755996
Right Arm D1 NMR : 0.280541
Right Arm Q3 power supply current : 300.777
Right Arm Q3 momentum : 0.755896
Right Arm Q3 gauss meter : -0.13535
Right Arm Q3 power supply polarity : enabled
Average current of the two cavities : 29.5548
Current on Unser monitor : 33.7281
Current on Upstream bcm : 29.4968
Current on Downstream bcm : 29.6127
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 29.6484
MBSY1c Hall A Beam energy : 5566.04
MBSY1c magnet current (amp) : 232.601
MBSY1c Bdl : 1.38901e+06
MBSY3c Hall C Beam energy : 5582.95
Tiefenbach Hall A energy : 5554.6
Tiefenbach Hall C energy : 5566
Delta(E)/E width (MV_AI_DXWID) : 0.627025
IPM1C12.XPOS : 0.00149617
IPM1H04A.XPOS : 0.0566964
IPM1H04A.YPOS : 0.00217013
IPM1H04B.XPOS : 0.0316274
IPM1H04B.YPOS : 0.0491638
Left Arm Collimator : 0.615381
Left LVDT HPM : -642
Left LVDT VPM : -14
HacL_HPE1313A:0_Ch58 : -0.15332
HacL_HPE1313A:0_Ch55 : 23.0957
HacL_HPE1313A:0_Ch54 : -0.231445
HacL_alignROLL : 0.127072
HacL_alignPITCH : -0.106967
HacL_alignHPT : -0
Right Arm Collimator : 0.612061
Right LVDT HPM : 387
Right LVDT VPM : 799
HacR_HPE1313A:0_Ch58 : -0.508301
HacR_HPE1313A:0_Ch55 : 21.7285
HacR_HPE1313A:0_Ch54 : -0.804688
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Wien angle : 12.4959
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 307.42
Wien field : 8.2213
Laser attenuation Hall A : 184
Laser power Hall A : 60
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : -5.5589
Target OTR y-position : 7.08516
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : Yes
Target OTR In/Out :
Arc OTR x-position : -1.12595
Arc OTR y-position : -0.330328
Arc OTR x-width : 2.96401
Arc OTR y-width : 2.94615
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0