NEXT
User name a-onl
Log entry time 07:40:33 on May 10, 2002
Entry number 3078
keyword=End_of_Run_1424
****************************
Run Number: 1424
End of Run Comment:
Run_type=production,beam_energy=5.562,beam_raster=on,comment_text=30 microamps beam - raster on - Q^2 = 4.1 dummy target Run,daq_mode=Unbuff,leftarm_p=+2.979,leftarm_theta=30.998,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=+0.756,rightarm_theta=65.663,target_name=4cm LH2,target_type=4cm Dummy
PRESCALE FACTORS:ps1=90 ps2=200 ps3=1 ps4=2 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 996953 [+]: 489201 [-]: 488011
TIME [0]: 70.737 mins [+]: 34.674 mins [-]: 34.675 mins
LIVE [0]: 94.91% [+]: 94.89% [-]: 94.90%
TRIGGER RATES: PRES/REAL
T1[0] :107.8/9699.7 Hz T2[0] :28.5/5693.9 Hz T3[0] :81.0/81.0 Hz T4[0] :27.1/54.2 Hz T5[0] : 3.1/3.1 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :107.8/9702.3 Hz T2[+] :28.5/5695.5 Hz T3[+] :81.2/81.2 Hz T4[+] :27.2/54.3 Hz T5[+] : 3.1/3.1 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :107.7/9696.7 Hz T2[-] :28.5/5692.5 Hz T3[-] :80.7/80.7 Hz T4[-] :27.0/54.1 Hz T5[-] : 3.2/3.2 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 457419/41167756 T2[0] : 120832/24166457 T3[0] : 343745/343745 T4[0] : 115035/230070 T5[0] : 13337/13337 T8[0] : 66/4346107
T1[+] : 224277/20184974 T2[+] : 59245/11849075 T3[+] : 168991/168991 T4[+] : 56490/112981 T5[+] : 6490/6490 T8[+] : 32/2130365
T1[-] : 224155/20173994 T2[-] : 59216/11843268 T3[-] : 167996/167996 T4[-] : 56262/112525 T5[-] : 6598/6598 T8[-] : 32/2130427
AVERAGE CURRENT
BCM x1 : 27.8252uA BCM x3 : 27.8989uA BCM x10: 27.8921uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 408.6 ppm BCM u3 : 394.5 ppm BCM u10: 397.1 ppm
BCM d1 : 412.9 ppm BCM d3 : 387.3 ppm BCM d10: 392.2 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.1155 BCM u3 [0]:0.116 BCM u10[0]:0.1162
BCM u1 [+]:0.05664 BCM u3 [+]:0.05687 BCM u10[+]:0.05698
BCM u1 [-]:0.05659 BCM u3 [-]:0.05682 BCM u10[-]:0.05694
BCM d1 [0]:0.1207 BCM d3 [0]:0.1209 BCM d10[0]:0.1206
BCM d1 [+]:0.05919 BCM d3 [+]:0.05926 BCM d10[+]:0.05912
BCM d1 [-]:0.05914 BCM d3 [-]:0.05922 BCM d10[-]:0.05907
****************************
End-of-run EPICS data for Run Number 1424 at Fri May 10 07:40:24 EDT 2002
Left Arm D1 momentum : 2.979
Left Arm arm angle : 30.9956
Right Arm D1 momentum : 0.755996
Right Arm arm angle : 65.663
Tiefenbach Hall A energy : 5554.59
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Top VDC Current : -2.97852
Left Arm Bottom VDC Current : -2.34375
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Left Arm Q1 power supply current : 2241.36
Left Arm Q1 momentum : 2.97923
Left Arm Q1 gauss meter : 0.18993
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1282.77
Left Arm Q2 momentum : 2.97904
Left Arm Q2 gauss meter : -0.675
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1042.42
Left Arm D1 momentum : 2.979
Left Arm D1 NMR : 1.10305
Left Arm Q3 power supply current : 1186.04
Left Arm Q3 momentum : 2.97912
Left Arm Q3 gauss meter : 0.5935
Left Arm Q3 power supply polarity : 0
Right Arm Q1 power supply current : 568.4
Right Arm Q1 momentum : 0.755917
Right Arm Q1 gauss meter : 0.01429
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 325.231
Right Arm Q2 momentum : 0.755706
Right Arm Q2 gauss meter : -0.17203
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 260.732
Right Arm D1 momentum : 0.755996
Right Arm D1 NMR : 0.280541
Right Arm Q3 power supply current : 300.841
Right Arm Q3 momentum : 0.756055
Right Arm Q3 gauss meter : -0.13536
Right Arm Q3 power supply polarity : enabled
Average current of the two cavities : 0.0308434
Current on Unser monitor : 4.04939
Current on Upstream bcm : 0.0351346
Current on Downstream bcm : 0.0265523
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
MBSY1c Hall A Beam energy : 5566.04
MBSY1c magnet current (amp) : 232.601
MBSY1c Bdl : 1.38901e+06
MBSY3c Hall C Beam energy : 5582.95
Tiefenbach Hall A energy : 5554.59
Tiefenbach Hall C energy : 5566
Delta(E)/E width (MV_AI_DXWID) : 1.24687
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Left Arm Collimator : 0.61543
Left LVDT HPM : -643
Left LVDT VPM : -12
HacL_HPE1313A:0_Ch58 : -0.152344
HacL_HPE1313A:0_Ch55 : 23.0957
HacL_HPE1313A:0_Ch54 : -0.232422
HacL_alignROLL : 0.126773
HacL_alignPITCH : -0.107115
HacL_alignHPT : -0
Right Arm Collimator : 0.612109
Right LVDT HPM : 383
Right LVDT VPM : 798
HacR_HPE1313A:0_Ch58 : -0.507812
HacR_HPE1313A:0_Ch55 : 21.6797
HacR_HPE1313A:0_Ch54 : -0.804199
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Wien angle : 12.4959
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 307.42
Wien field : 8.2213
Laser attenuation Hall A : 100
Laser power Hall A : 60
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : -5.5589
Target OTR y-position : 7.08516
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : No
Target OTR In/Out : Current is Low
Arc OTR x-position : -1.22946
Arc OTR y-position : -0.298879
Arc OTR x-width : 2.9496
Arc OTR y-width : 2.97307
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0