    User name a-onl

    Log entry time 17:56:03 on May 11, 2002

    Entry number 3244

    keyword=Start_Run_1491,Run_type=other,beam_energy=3.36,beam_raster=off,comment_text=70uA beam - Thin Carbon target, pointing run.,daq_mode=Unbuff,leftarm_p=+2.979,leftarm_theta=20.257,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=+0.756,rightarm_theta=63.191,target_name=Thin Carbon,target_type=Carbon (thin)
    Beginning-of-run EPICS data for Run Number 1491 at Sat May 11 17:55:51 EDT 2002
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ; PS1 for the Right spectrometer based on T1 defined by S1*S2
    ; PS2 for the Right spectrometer based on T2 defined by S1+S2
    ; PS3 for the Left spectrometer based on T3 defined by S1*S2
    ; PS4 for the Left spectrometer redundant trigger T4 S1*S0+S2*S0
    ; PS5 for coincidence of T1 and T3.
    ; PS7 irrelevant
    ; PS8 for pulser 
    ps1=40,ps2=110,ps3=1,ps4=1,ps5=1,ps6=65535,ps7=65535,ps8=65535
     
    Left Arm Q1 power supply current : 2241.33
    Left Arm Q1 momentum : 2.97918
    Left Arm Q1 gauss meter : 0.18993
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1282.73
    Left Arm Q2 momentum : 2.97894
    Left Arm Q2 gauss meter : -0.6751
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1042.57
    Left Arm D1 momentum : 2.979
    Left Arm D1 NMR : 1.10305
    Left Arm Q3 power supply current : 1186.11
    Left Arm Q3 momentum : 2.97929
    Left Arm Q3 gauss meter : 0.5936
    Left Arm Q3 power supply polarity : 0
    Right Arm Q1 power supply current : 568.4
    Right Arm Q1 momentum : 0.755917
    Right Arm Q1 gauss meter : 0.014286
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 325.186
    Right Arm Q2 momentum : 0.755602
    Right Arm Q2 gauss meter : -0.17204
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 260.74
    Right Arm D1 momentum : 0.755999
    Right Arm D1 NMR : 0.280542
    Right Arm Q3 power supply current : 300.843
    Right Arm Q3 momentum : 0.756061
    Right Arm Q3 gauss meter : -0.13533
    Right Arm Q3 power supply polarity : enabled
    Left Arm Top VDC Current : -2.73438
    Left Arm Bottom VDC Current : -1.85547
    Right Arm Top VDC Current :
    Right Arm Bottom VDC Current :
    Average current of the two cavities : 69.3762
    Current on Unser monitor : 73.9989
    Current on Upstream bcm : 69.1756
    Current on Downstream bcm : 69.6793
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 69.2487
    Tiefenbach Hall A energy : 3358.65
    Tiefenbach Hall C energy : 5566
    Delta(E)/E width (MV_AI_DXWID) : 0
    MBSY1c Hall A Beam energy : 3363.97
    MBSY3c Hall C Beam energy : 5582.95
    MBSY1c magnet current (amp) : 140.095
    MBSY1c Bdl : 839483
    Arc1 dp/p : 0.000115164
    Arc2 dp/p : -0.00148112
    Left Arm Arm Collimator : 0.615479
    Left LVDT HPM : -725
    Left LVDT VPM : 1135
    HacL_HPE1313A:0_Ch58 : -0.137695
    HacL_HPE1313A:0_Ch55 : 22.8516
    HacL_HPE1313A:0_Ch54 : -0.0922852
    HacL_alignROLL : 0.252712
    HacL_alignPITCH : -0.120712
    HacL_alignHPT : -0
    Left Arm Angle Floor Angle : 28.25
    Left Arm Angle Vernier : -3.9
    Left Arm Scattering Angle : 28.0485
    Right Arm Arm Collimator : 0.612109
    Right LVDT HPM : 446
    Right LVDT VPM : 893
    HacR_HPE1313A:0_Ch58 : -0.494141
    HacR_HPE1313A:0_Ch55 : 21.6797
    HacR_HPE1313A:0_Ch54 : -0.82666
    HacR_alignROLL : 0.466989
    HacR_alignPITCH : -0.489172
    HacR_alignHPT : -0
    Right Arm Angle Floor Angle : 63
    Right Arm Angle Vernier : -1.1
    Right Arm Scattering Angle : 63.1907
    IPM1C12.XPOS : -0.00633287
    IPM1C12.YPOS : 0.0167331
    IPM1H04A.XPOS : -0.0240372
    IPM1H04A.YPOS : -0.0801694
    IPM1H04B.XPOS : 0.0162581
    IPM1H04B.YPOS : 0.0401836
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle : 12.4959
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 307.42
    Wien field : 8.2213
    Laser attenuation Hall A : 304
    Laser power Hall A : 60
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 2.67796
    Target OTR y-position : 0.175871
    Target OTR x-width : 0.323235
    Target OTR y-width : 0.22837
    Target OTR data valid flag : No
    Target OTR In/Out : MaxPix is Bad
    Arc OTR x-position : -1.12538
    Arc OTR y-position : -0.281373
    Arc OTR x-width : 2.97367
    Arc OTR y-width : 2.94998
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0