Log entry time 16:51:48 on May 13, 2002
Entry number 3388
keyword=End_of_Run_1554
****************************
Run Number: 1554
End of Run Comment:
Run_type=coincidence,beam_energy=3.36,beam_raster=on,comment_text=LH2 4cm coinc,daq_mode=Unbuff,leftarm_p=+2.979,leftarm_theta=20.257,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=-1.1771,rightarm_theta=61.184,target_name=LH2,target_type=4cm Hydrogen
PRESCALE FACTORS:ps1=1 ps2=100 ps3=1 ps4=1 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 998495 [+]: 489919 [-]: 488824
TIME [0]: 41.281 mins [+]: 20.234 mins [-]: 20.237 mins
LIVE [0]: 89.91% [+]: 89.91% [-]: 89.93%
TRIGGER RATES: PRES/REAL
T1[0] :31.2/31.2 Hz T2[0] :72.7/7274.2 Hz T3[0] :217.2/217.2 Hz T4[0] :121.9/121.9 Hz T5[0] : 5.3/5.3 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :31.4/31.4 Hz T2[+] :72.8/7278.0 Hz T3[+] :217.2/217.2 Hz T4[+] :122.2/122.2 Hz T5[+] : 5.3/5.3 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :31.0/31.0 Hz T2[-] :72.7/7270.4 Hz T3[-] :217.2/217.2 Hz T4[-] :121.6/121.6 Hz T5[-] : 5.2/5.2 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 77347/77347 T2[0] : 180173/18017343 T3[0] : 537945/537945 T4[0] : 302040/302040 T5[0] : 13019/13019 T8[0] : 38/2536331
T1[+] : 38156/38156 T2[+] : 88356/8835673 T3[+] : 263633/263633 T4[+] : 148320/148320 T5[+] : 6421/6421 T8[+] : 18/1243170
T1[-] : 37592/37592 T2[-] : 88279/8827914 T3[-] : 263736/263736 T4[-] : 147618/147618 T5[-] : 6324/6324 T8[-] : 18/1243375
AVERAGE CURRENT
BCM x1 : 65.2404uA BCM x3 : 65.3908uA BCM x10: 58.2142uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 419.8 ppm BCM u3 : 404.6 ppm BCM u10: 317.4 ppm
BCM d1 : 421.1 ppm BCM d3 : 395.1 ppm BCM d10: 111 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.1578 BCM u3 [0]:0.1586 BCM u10[0]:0.1504
BCM u1 [+]:0.07738 BCM u3 [+]:0.07775 BCM u10[+]:0.07375
BCM u1 [-]:0.07733 BCM u3 [-]:0.0777 BCM u10[-]:0.07371
BCM d1 [0]:0.1654 BCM d3 [0]:0.1654 BCM d10[0]:0.138
BCM d1 [+]:0.0811 BCM d3 [+]:0.08109 BCM d10[+]:0.06763
BCM d1 [-]:0.08104 BCM d3 [-]:0.08104 BCM d10[-]:0.06763
****************************
End-of-run EPICS data for Run Number 1554 at Mon May 13 16:51:39 EDT 2002
Left Arm D1 momentum : 2.979
Left Arm arm angle : 20.2566
Right Arm D1 momentum : 1.17702
Right Arm arm angle : 61.184
Tiefenbach Hall A energy : 3358.62
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Top VDC Current : -3.17383
Left Arm Bottom VDC Current : 2.09961
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Left Arm Q1 power supply current : 2241.26
Left Arm Q1 momentum : 2.97909
Left Arm Q1 gauss meter : 0.18989
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1282.66
Left Arm Q2 momentum : 2.97877
Left Arm Q2 gauss meter : -0.6749
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1042.55
Left Arm D1 momentum : 2.979
Left Arm D1 NMR : 1.10305
Left Arm Q3 power supply current : 1186.16
Left Arm Q3 momentum : 2.97941
Left Arm Q3 gauss meter : 0.5935
Left Arm Q3 power supply polarity : 0
Right Arm Q1 power supply current : 885.08
Right Arm Q1 momentum : 1.17707
Right Arm Q1 gauss meter : -0.022049
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 506.686
Right Arm Q2 momentum : 1.17733
Right Arm Q2 gauss meter : 0.2662
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 404.183
Right Arm D1 momentum : 1.17702
Right Arm D1 NMR : 0.436778
Right Arm Q3 power supply current : 468.436
Right Arm Q3 momentum : 1.17724
Right Arm Q3 gauss meter : 0.21
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 69.3323
Current on Unser monitor : 73.5052
Current on Upstream bcm : 69.0376
Current on Downstream bcm : 69.627
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 69.3062
MBSY1c Hall A Beam energy : 3363.97
MBSY1c magnet current (amp) : 140.095
MBSY1c Bdl : 839483
MBSY3c Hall C Beam energy : 5582.94
Tiefenbach Hall A energy : 3358.62
Tiefenbach Hall C energy : 5565.99
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : -0.00706184
IPM1H04A.XPOS : 1.03443
IPM1H04A.YPOS : -0.0198191
IPM1H04B.XPOS : -0.0414906
IPM1H04B.YPOS : -0.0360382
Left Arm Collimator : 0.615527
Left LVDT HPM : -680
Left LVDT VPM : 963
HacL_HPE1313A:0_Ch58 : -0.134277
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.103516
HacL_alignROLL : 0.243816
HacL_alignPITCH : -0.124586
HacL_alignHPT : -0
Right Arm Collimator : 0.612061
Right LVDT HPM : 385
Right LVDT VPM : 670
HacR_HPE1313A:0_Ch58 : -0.494141
HacR_HPE1313A:0_Ch55 : 22.0215
HacR_HPE1313A:0_Ch54 : -0.837402
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Wien angle : 12.4959
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 307.42
Wien field : 8.2213
Laser attenuation Hall A : 331
Laser power Hall A : 60
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : 2.74908
Target OTR y-position : 0.134591
Target OTR x-width : 0.513013
Target OTR y-width : 0.600849
Target OTR data valid flag : Yes
Target OTR In/Out :
Arc OTR x-position : -1.10547
Arc OTR y-position : -0.311222
Arc OTR x-width : 2.97051
Arc OTR y-width : 2.93258
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0