Log entry time 19:36:51 on May 13, 2002
Entry number 3396
keyword=End_of_Run_1558
****************************
Run Number: 1558
End of Run Comment:
Run_type=coincidence,beam_energy=3.36,beam_raster=on,comment_text=LH2 4cm coinc,daq_mode=Unbuff,leftarm_p=+2.979,leftarm_theta=20.257,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=-1.1771,rightarm_theta=61.184,target_name=LH2,target_type=4cm Hydrogen
PRESCALE FACTORS:ps1=1 ps2=100 ps3=1 ps4=1 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 998698 [+]: 489431 [-]: 489477
TIME [0]: 41.679 mins [+]: 20.428 mins [-]: 20.429 mins
LIVE [0]: 89.80% [+]: 89.80% [-]: 89.81%
TRIGGER RATES: PRES/REAL
T1[0] :31.2/31.2 Hz T2[0] :72.4/7244.1 Hz T3[0] :215.1/215.1 Hz T4[0] :120.7/120.7 Hz T5[0] : 5.3/5.3 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :31.1/31.1 Hz T2[+] :72.5/7246.0 Hz T3[+] :215.2/215.2 Hz T4[+] :120.5/120.5 Hz T5[+] : 5.4/5.4 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :31.3/31.3 Hz T2[-] :72.4/7243.1 Hz T3[-] :214.8/214.8 Hz T4[-] :120.9/120.9 Hz T5[-] : 5.2/5.2 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 78081/78081 T2[0] : 181157/18115742 T3[0] : 537849/537849 T4[0] : 301787/301787 T5[0] : 13257/13257 T8[0] : 39/2560786
T1[+] : 38178/38178 T2[+] : 88813/8881324 T3[+] : 263765/263765 T4[+] : 147645/147645 T5[+] : 6575/6575 T8[+] : 19/1255102
T1[-] : 38358/38358 T2[-] : 88782/8878200 T3[-] : 263270/263270 T4[-] : 148141/148141 T5[-] : 6425/6425 T8[-] : 19/1255163
AVERAGE CURRENT
BCM x1 : 64.2537uA BCM x3 : 64.4018uA BCM x10: 57.3201uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 386.5 ppm BCM u3 : 371.6 ppm BCM u10: 283.3 ppm
BCM d1 : 387.6 ppm BCM d3 : 362.4 ppm BCM d10: 78.28 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.1569 BCM u3 [0]:0.1577 BCM u10[0]:0.1495
BCM u1 [+]:0.07694 BCM u3 [+]:0.07731 BCM u10[+]:0.07329
BCM u1 [-]:0.07688 BCM u3 [-]:0.07725 BCM u10[-]:0.07325
BCM d1 [0]:0.1645 BCM d3 [0]:0.1644 BCM d10[0]:0.1372
BCM d1 [+]:0.08064 BCM d3 [+]:0.08063 BCM d10[+]:0.06725
BCM d1 [-]:0.08058 BCM d3 [-]:0.08058 BCM d10[-]:0.06725
****************************
End-of-run EPICS data for Run Number 1558 at Mon May 13 19:36:42 EDT 2002
Left Arm D1 momentum : 2.979
Left Arm arm angle : 20.2566
Right Arm D1 momentum : 1.17702
Right Arm arm angle : 61.184
Tiefenbach Hall A energy : 3358.64
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Top VDC Current : 2.63672
Left Arm Bottom VDC Current : -0.195312
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Left Arm Q1 power supply current : 2241.33
Left Arm Q1 momentum : 2.97918
Left Arm Q1 gauss meter : 0.18988
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1282.79
Left Arm Q2 momentum : 2.97908
Left Arm Q2 gauss meter : -0.6749
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1042.56
Left Arm D1 momentum : 2.979
Left Arm D1 NMR : 1.10305
Left Arm Q3 power supply current : 1186.1
Left Arm Q3 momentum : 2.97927
Left Arm Q3 gauss meter : 0.5936
Left Arm Q3 power supply polarity : 0
Right Arm Q1 power supply current : 885.08
Right Arm Q1 momentum : 1.17707
Right Arm Q1 gauss meter : -0.022064
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 506.637
Right Arm Q2 momentum : 1.17722
Right Arm Q2 gauss meter : 0.2662
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 404.183
Right Arm D1 momentum : 1.17702
Right Arm D1 NMR : 0.436778
Right Arm Q3 power supply current : 468.321
Right Arm Q3 momentum : 1.17695
Right Arm Q3 gauss meter : 0.2099
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 69.5102
Current on Unser monitor : 73.0132
Current on Upstream bcm : 69.3387
Current on Downstream bcm : 69.6816
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 69.4891
MBSY1c Hall A Beam energy : 3363.97
MBSY1c magnet current (amp) : 140.095
MBSY1c Bdl : 839483
MBSY3c Hall C Beam energy : 5582.94
Tiefenbach Hall A energy : 3358.64
Tiefenbach Hall C energy : 5565.99
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0.00813577
IPM1H04A.XPOS : 1.04739
IPM1H04A.YPOS : -0.0311974
IPM1H04B.XPOS : -0.0503436
IPM1H04B.YPOS : -0.023994
Left Arm Collimator : 0.61543
Left LVDT HPM : -683
Left LVDT VPM : 954
HacL_HPE1313A:0_Ch58 : -0.132812
HacL_HPE1313A:0_Ch55 : 23.584
HacL_HPE1313A:0_Ch54 : -0.102051
HacL_alignROLL : 0.24529
HacL_alignPITCH : -0.125171
HacL_alignHPT : -0
Right Arm Collimator : 0.612012
Right LVDT HPM : 386
Right LVDT VPM : 662
HacR_HPE1313A:0_Ch58 : -0.492188
HacR_HPE1313A:0_Ch55 : 22.0703
HacR_HPE1313A:0_Ch54 : -0.836914
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Wien angle : 12.4959
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 307.42
Wien field : 8.2213
Laser attenuation Hall A : 334
Laser power Hall A : 60
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : 2.75186
Target OTR y-position : 0.103351
Target OTR x-width : 0.522814
Target OTR y-width : 0.596571
Target OTR data valid flag : Yes
Target OTR In/Out :
Arc OTR x-position : -1.15662
Arc OTR y-position : -0.289249
Arc OTR x-width : 2.97129
Arc OTR y-width : 2.93387
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0