NEXT
User name a-onl
Log entry time 02:33:30 on May 18, 2002
Entry number 3541
keyword=End_of_Run_1605
****************************
Run Number: 1605
End of Run Comment:
Run_type=other,beam_energy=2.842,beam_raster=on,comment_text=(spectro + target) cover OFF 4cm Dummy,daq_mode=Unbuff,leftarm_p=+2.149,leftarm_theta=29.462,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=+0.756,rightarm_theta=62.029,target_name=4cm Dummy,target_type=4cm Dummy
PRESCALE FACTORS:ps1=30 ps2=200 ps3=1 ps4=2 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 89566 [+]: 43979 [-]: 43887
TIME [0]: 4.419 mins [+]: 2.165 mins [-]: 2.166 mins
LIVE [0]: 89.66% [+]: 89.57% [-]: 89.84%
TRIGGER RATES: PRES/REAL
T1[0] :177.5/5326.3 Hz T2[0] :19.6/3926.3 Hz T3[0] :157.0/157.0 Hz T4[0] :19.3/38.6 Hz T5[0] : 3.2/3.2 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :177.8/5334.7 Hz T2[+] :19.7/3934.3 Hz T3[+] :157.8/157.8 Hz T4[+] :19.3/38.6 Hz T5[+] : 3.3/3.3 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :177.3/5318.5 Hz T2[-] :19.6/3919.4 Hz T3[-] :156.4/156.4 Hz T4[-] :19.4/38.8 Hz T5[-] : 3.2/3.2 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 47071/1412144 T2[0] : 5204/1040962 T3[0] : 41635/41635 T4[0] : 5116/10232 T5[0] : 861/861 T8[0] : 4/271489
T1[+] : 23104/693128 T2[+] : 2555/511172 T3[+] : 20503/20503 T4[+] : 2505/5011 T5[+] : 429/429 T8[+] : 2/133046
T1[-] : 23041/691238 T2[-] : 2547/509405 T3[-] : 20321/20321 T4[-] : 2519/5039 T5[-] : 418/418 T8[-] : 2/133089
AVERAGE CURRENT
BCM x1 : 15.9173uA BCM x3 : 7.8026 uA BCM x10: 15.9624uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 915.6 ppm BCM u3 : 893.4 ppm BCM u10: 895.2 ppm
BCM d1 : 934 ppm BCM d3 : 1E+39 ppm BCM d10: 883.7 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.004129 BCM u3 [0]:0.00414 BCM u10[0]:0.004151
BCM u1 [+]:0.002025 BCM u3 [+]:0.002031 BCM u10[+]:0.002036
BCM u1 [-]:0.002022 BCM u3 [-]:0.002028 BCM u10[-]:0.002033
BCM d1 [0]:0.004311 BCM d3 [0]:-3.119E-06 BCM d10[0]:0.004313
BCM d1 [+]:0.002115 BCM d3 [+]:-1.526E-06 BCM d10[+]:0.002116
BCM d1 [-]:0.002112 BCM d3 [-]:-1.529E-06 BCM d10[-]:0.002112
****************************
End-of-run EPICS data for Run Number 1605 at Sat May 18 02:33:21 EDT 2002
Left Arm D1 momentum : 2.14886
Left Arm arm angle : 29.4622
Right Arm D1 momentum : 0.755998
Right Arm arm angle : 62.0306
Tiefenbach Hall A energy : 2844.72
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Top VDC Current : -1.31836
Left Arm Bottom VDC Current : 1.36719
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Left Arm Q1 power supply current : 1616.9
Left Arm Q1 momentum : 2.14918
Left Arm Q1 gauss meter : 0.13721
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 925.61
Left Arm Q2 momentum : 2.14958
Left Arm Q2 gauss meter : -0.4873
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 732.69
Left Arm D1 momentum : 2.14886
Left Arm D1 NMR : 0.79512
Left Arm Q3 power supply current : 855.582
Left Arm Q3 momentum : 2.14906
Left Arm Q3 gauss meter : 0.4281
Left Arm Q3 power supply polarity : 0
Right Arm Q1 power supply current : 568.505
Right Arm Q1 momentum : 0.756056
Right Arm Q1 gauss meter : 0.014276
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 325.186
Right Arm Q2 momentum : 0.7556
Right Arm Q2 gauss meter : -0.17204
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 260.589
Right Arm D1 momentum : 0.755998
Right Arm D1 NMR : 0.280542
Right Arm Q3 power supply current : 300.665
Right Arm Q3 momentum : 0.755613
Right Arm Q3 gauss meter : -0.13535
Right Arm Q3 power supply polarity : enabled
Average current of the two cavities : 19.9484
Current on Unser monitor : 22.9616
Current on Upstream bcm : 19.8817
Current on Downstream bcm : 20.015
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 19.9826
MBSY1c Hall A Beam energy : 2849.17
MBSY1c magnet current (amp) : 118.6
MBSY1c Bdl : 711013
MBSY3c Hall C Beam energy : 1986.36
Tiefenbach Hall A energy : 2844.79
Tiefenbach Hall C energy : 1981.86
Delta(E)/E width (MV_AI_DXWID) : 0.342001
IPM1C12.XPOS : 0.0650481
IPM1H04A.XPOS : 0.73366
IPM1H04A.YPOS : 0.432995
IPM1H04B.XPOS : 0.00581688
IPM1H04B.YPOS : -0.158039
Left Arm Collimator : 0.615479
Left LVDT HPM : 1448
Left LVDT VPM : 204
HacL_HPE1313A:0_Ch58 : -0.154785
HacL_HPE1313A:0_Ch55 : 24.1699
HacL_HPE1313A:0_Ch54 : -0.255859
HacL_alignROLL : 0.107508
HacL_alignPITCH : -0.108231
HacL_alignHPT : -0
Right Arm Collimator : 0.612061
Right LVDT HPM : -756
Right LVDT VPM : 1206
HacR_HPE1313A:0_Ch58 : -0.473633
HacR_HPE1313A:0_Ch55 : 22.7539
HacR_HPE1313A:0_Ch54 : -0.832031
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Wien angle : 80.233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1866.3
Wien field : 53.472
Laser attenuation Hall A : 172
Laser power Hall A : 60
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : 2.53487
Target OTR y-position : 0.301727
Target OTR x-width : 0.758695
Target OTR y-width : 0.776279
Target OTR data valid flag : Yes
Target OTR In/Out :
Arc OTR x-position : -1.11952
Arc OTR y-position : -0.31996
Arc OTR x-width : 2.95727
Arc OTR y-width : 2.94023
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0