NEXT
User name a-onl
Log entry time 03:36:18 on May 19, 2002
Entry number 3669
keyword=End_of_Run_1661
****************************
Run Number: 1661
End of Run Comment:
Run_type=production,beam_energy=2.842,beam_raster=on,comment_text=(spectro + target) cover OFF 4cm Hydrogen Raster ON,daq_mode=Unbuff,leftarm_p=+2.979,leftarm_theta=12.682,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=+0.756,rightarm_theta=62.029,target_name=4cm Hydrogen,target_type=4cm Hydrogen
PRESCALE FACTORS:ps1=100 ps2=100 ps3=1 ps4=2 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 1002264 [+]: 491500 [-]: 491506
TIME [0]: 22.316 mins [+]: 10.943 mins [-]: 10.946 mins
LIVE [0]: 86.01% [+]: 86.01% [-]: 86.02%
TRIGGER RATES: PRES/REAL
T1[0] :257.7/25773.3 Hz T2[0] :118.0/11804.4 Hz T3[0] :372.9/372.9 Hz T4[0] :117.3/234.7 Hz T5[0] : 4.3/4.3 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :258.1/25805.3 Hz T2[+] :118.2/11819.6 Hz T3[+] :372.3/372.3 Hz T4[+] :117.4/234.8 Hz T5[+] : 4.3/4.3 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :257.4/25741.4 Hz T2[-] :117.9/11789.6 Hz T3[-] :373.2/373.2 Hz T4[-] :117.2/234.4 Hz T5[-] : 4.2/4.2 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 345093/34509360 T2[0] : 158055/15805577 T3[0] : 499243/499243 T4[0] : 157124/314248 T5[0] : 5696/5696 T8[0] : 20/1371091
T1[+] : 169439/16943970 T2[+] : 77608/7760861 T3[+] : 244428/244428 T4[+] : 77102/154204 T5[+] : 2829/2829 T8[+] : 10/672368
T1[-] : 169063/16906336 T2[-] : 77431/7743143 T3[-] : 245132/245132 T4[-] : 76976/153952 T5[-] : 2745/2745 T8[-] : 10/672539
AVERAGE CURRENT
BCM x1 : 65.8787uA BCM x3 : 32.3493uA BCM x10: 58.1645uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 1298 ppm BCM u3 : 1266 ppm BCM u10: 973.6 ppm
BCM d1 : 1299 ppm BCM d3 : 1E+39 ppm BCM d10: 271.6 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.08623 BCM u3 [0]:0.08664 BCM u10[0]:0.08216
BCM u1 [+]:0.04234 BCM u3 [+]:0.04254 BCM u10[+]:0.04033
BCM u1 [-]:0.04224 BCM u3 [-]:0.04245 BCM u10[-]:0.04026
BCM d1 [0]:0.09018 BCM d3 [0]:-1.539E-05 BCM d10[0]:0.0736
BCM d1 [+]:0.04428 BCM d3 [+]:-7.573E-06 BCM d10[+]:0.0361
BCM d1 [-]:0.04418 BCM d3 [-]:-7.516E-06 BCM d10[-]:0.03609
****************************
End-of-run EPICS data for Run Number 1661 at Sun May 19 03:36:02 EDT 2002
Left Arm D1 momentum : 2.97901
Left Arm arm angle : 12.6815
Right Arm D1 momentum : 0.755999
Right Arm arm angle : 62.0306
Tiefenbach Hall A energy : 2844.73
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Top VDC Current : -1.66016
Left Arm Bottom VDC Current : 2.63672
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Left Arm Q1 power supply current : 2241.26
Left Arm Q1 momentum : 2.97909
Left Arm Q1 gauss meter : 0.18991
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1282.88
Left Arm Q2 momentum : 2.97927
Left Arm Q2 gauss meter : -0.675
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1042.77
Left Arm D1 momentum : 2.97901
Left Arm D1 NMR : 1.10305
Left Arm Q3 power supply current : 1186.01
Left Arm Q3 momentum : 2.97903
Left Arm Q3 gauss meter : 0.5935
Left Arm Q3 power supply polarity : 0
Right Arm Q1 power supply current : 568.4
Right Arm Q1 momentum : 0.755917
Right Arm Q1 gauss meter : 0.014291
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 325.175
Right Arm Q2 momentum : 0.755576
Right Arm Q2 gauss meter : -0.17193
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 260.58
Right Arm D1 momentum : 0.755996
Right Arm D1 NMR : 0.280541
Right Arm Q3 power supply current : 300.965
Right Arm Q3 momentum : 0.755973
Right Arm Q3 gauss meter : -0.13536
Right Arm Q3 power supply polarity : enabled
Average current of the two cavities : 69.9186
Current on Unser monitor : 74.5599
Current on Upstream bcm : 69.6673
Current on Downstream bcm : 70.0084
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 70.1273
MBSY1c Hall A Beam energy : 2849.17
MBSY1c magnet current (amp) : 118.6
MBSY1c Bdl : 711013
MBSY3c Hall C Beam energy : 1986.36
Tiefenbach Hall A energy : 2844.73
Tiefenbach Hall C energy : 1981.86
Delta(E)/E width (MV_AI_DXWID) : 0.357267
IPM1C12.XPOS : 0.00597072
IPM1H04A.XPOS : 0.726845
IPM1H04A.YPOS : 0.275434
IPM1H04B.XPOS : -0.0618018
IPM1H04B.YPOS : 0.0162603
Left Arm Collimator : 0.615479
Left LVDT HPM : 1362
Left LVDT VPM : 434
HacL_HPE1313A:0_Ch58 : -0.233887
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : 0.106934
HacL_alignROLL : 0.443645
HacL_alignPITCH : -0.0560694
HacL_alignHPT : -0
Right Arm Collimator : 0.612158
Right LVDT HPM : -747
Right LVDT VPM : 1119
HacR_HPE1313A:0_Ch58 : -0.479004
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -0.837402
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Wien angle : 80.233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1866.3
Wien field : 53.472
Laser attenuation Hall A : 349
Laser power Hall A : 60
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : 2.69257
Target OTR y-position : 0.304377
Target OTR x-width : 0.699779
Target OTR y-width : 0.794983
Target OTR data valid flag : Yes
Target OTR In/Out :
Arc OTR x-position : -1.11268
Arc OTR y-position : -0.340071
Arc OTR x-width : 2.99538
Arc OTR y-width : 2.93261
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0