keyword=Day Shift summary 5/19/02
8:00 Changing to Q2 = 2.64 GeV (left) KINI-COIN
9:20 Q3 right quench, can't immediately reset
9:40 argon gas out; both bottles changed
call for access for quench
9:53 Mark and John access to reset Q3
still waiting for right dipole to reach proper setting
10:05 Quench fault cleared, but recurred when current raised. Ed coming in.
10:45 Noted that dipole field regulation was OFF. Turned it ON. Dipole then
quickly came to correct setting. (Regulator turned off automatically when
polarity changed.)
11:03 Mark Stevens in to fix crosstalk between Q3 leads.
12:07 Q3 OK. Can be controlled remotely.
12:15 Beam in Hall. Q3 being recycled.
12:23 Trigger changed
12:46 Start run 1668 C tgt
13:01 End 1368 287 K events Change tgt to 4 cm LH2
13:10 Start 1669 Coinc No cap
13:44 Stop 1669
13:46 Start 1670
14:18 Stop 1670
14:19 Start 1671
14:53 Stop 1671
14:53 Start 1672
15:25 Stop 1672
15:26 Start 1673
15:59 Stop 1673
15:59 Start 1674