    8:00 Changing to Q2 = 2.64 GeV (left) KINI-COIN
    9:20 Q3 right quench, can't immediately reset
    9:40 argon gas out; both bottles changed
    call for access for quench
    9:53 Mark and John access to reset Q3
    still waiting for right dipole to reach proper setting
    10:05 Quench fault cleared, but recurred when current raised. Ed coming in.
    10:45 Noted that dipole field regulation was OFF. Turned it ON. Dipole then
    quickly came to correct setting. (Regulator turned off automatically when
    polarity changed.)
    11:03 Mark Stevens in to fix crosstalk between Q3 leads.
    12:07 Q3 OK. Can be controlled remotely.
    12:15 Beam in Hall. Q3 being recycled.
    12:23 Trigger changed
    12:46 Start run 1668 C tgt
    13:01 End 1368 287 K events Change tgt to 4 cm LH2
    13:10 Start 1669 Coinc No cap
    13:44 Stop 1669
    13:46 Start 1670
    14:18 Stop 1670
    14:19 Start 1671
    14:53 Stop 1671
    14:53 Start 1672
    15:25 Stop 1672
    15:26 Start 1673
    15:59 Stop 1673
    15:59 Start 1674