NEXT
User name a-onl
Log entry time 00:55:22 on May 24, 2002
Entry number 4163
keyword=End_of_Run_1854
****************************
Run Number: 1854
End of Run Comment:
Run_type=production,beam_energy=3.772,beam_raster=on,comment_text=4 cm LH2,I=70uA,raster on,daq_mode=Unbuff,leftarm_p=+2.979,leftarm_theta=23.665,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,rightarm_p=+0.756,rightarm_theta=63.876,target_name=4 cm LH2,target_type=4cm Hydrogen
PRESCALE FACTORS:ps1=100 ps=200 ps3=1 ps4=2 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 999899 [+]: 491060 [-]: 489804
TIME [0]: 34.166 mins [+]: 16.755 mins [-]: 16.756 mins
LIVE [0]: 4.19% [+]: 4.19% [-]: 4.18%
TRIGGER RATES: PRES/REAL
T1[0] :280.7/28072.1 Hz T2[0] :11125.1/11125.1 Hz T3[0] :183.5/183.5 Hz T4[0] :61.7/123.4 Hz T5[0] : 3.6/3.6 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :281.2/28120.7 Hz T2[+] :11136.0/11136.0 Hz T3[+] :183.7/183.7 Hz T4[+] :61.8/123.7 Hz T5[+] : 3.7/3.7 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :280.2/28022.6 Hz T2[-] :11113.4/11113.4 Hz T3[-] :183.2/183.2 Hz T4[-] :61.6/123.2 Hz T5[-] : 3.6/3.6 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 575462/57546228 T2[0] :22805776/22805776 T3[0] : 376170/376170 T4[0] : 126519/253039 T5[0] : 7476/7476 T8[0] : 32/2099142
T1[+] : 282691/28269109 T2[+] :11194815/11194815 T3[+] : 184634/184634 T4[+] : 62161/124322 T5[+] : 3699/3699 T8[+] : 15/1029404
T1[-] : 281726/28172692 T2[-] :11172905/11172905 T3[-] : 184231/184231 T4[-] : 61931/123863 T5[-] : 3612/3612 T8[-] : 15/1029485
AVERAGE CURRENT
BCM x1 : 68.3047uA BCM x3 : 68.4570uA BCM x10: 59.5681uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 1537 ppm BCM u3 : 1497 ppm BCM u10: 1127 ppm
BCM d1 : 1537 ppm BCM d3 : 1466 ppm BCM d10: 209.7 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.1371 BCM u3 [0]:0.1378 BCM u10[0]:0.1305
BCM u1 [+]:0.06734 BCM u3 [+]:0.06765 BCM u10[+]:0.06405
BCM u1 [-]:0.06714 BCM u3 [-]:0.06746 BCM u10[-]:0.06391
BCM d1 [0]:0.1429 BCM d3 [0]:0.1429 BCM d10[0]:0.1138
BCM d1 [+]:0.0702 BCM d3 [+]:0.07018 BCM d10[+]:0.05579
BCM d1 [-]:0.06999 BCM d3 [-]:0.06998 BCM d10[-]:0.05577
****************************
End-of-run EPICS data for Run Number 1854 at Fri May 24 00:55:10 EDT 2002
Left Arm D1 momentum : 2.97901
Left Arm arm angle : 23.6654
Right Arm D1 momentum : 0.755999
Right Arm arm angle : 63.8768
Tiefenbach Hall A energy : 3772.73
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Top VDC Current : 3.71094
Left Arm Bottom VDC Current : 3.27148
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Left Arm Q1 power supply current : 2241.26
Left Arm Q1 momentum : 2.97909
Left Arm Q1 gauss meter : 0.18995
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1282.87
Left Arm Q2 momentum : 2.97911
Left Arm Q2 gauss meter : -0.6751
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1042.52
Left Arm D1 momentum : 2.97901
Left Arm D1 NMR : 1.10305
Left Arm Q3 power supply current : 1185.96
Left Arm Q3 momentum : 2.9789
Left Arm Q3 gauss meter : 0.5935
Left Arm Q3 power supply polarity : 0
Right Arm Q1 power supply current : 568.54
Right Arm Q1 momentum : 0.756103
Right Arm Q1 gauss meter : 0.014288
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 325.348
Right Arm Q2 momentum : 0.755977
Right Arm Q2 gauss meter : -0.17205
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 260.563
Right Arm D1 momentum : 0.755998
Right Arm D1 NMR : 0.280542
Right Arm Q3 power supply current : 300.825
Right Arm Q3 momentum : 0.756016
Right Arm Q3 gauss meter : -0.1354
Right Arm Q3 power supply polarity : enabled
Average current of the two cavities : 69.8955
Current on Unser monitor : 74.0634
Current on Upstream bcm : 69.8092
Current on Downstream bcm : 69.7705
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 70.5711
MBSY1c Hall A Beam energy : 3779.49
MBSY1c magnet current (amp) : 157.467
MBSY1c Bdl : 943175
MBSY3c Hall C Beam energy : 4720.13
Tiefenbach Hall A energy : 3772.73
Tiefenbach Hall C energy : 4705.59
Delta(E)/E width (MV_AI_DXWID) : 1.22629
IPM1C12.XPOS : 0.00933632
IPM1H04A.XPOS : 0.795424
IPM1H04A.YPOS : 0.549903
IPM1H04B.XPOS : -0.0425229
IPM1H04B.YPOS : -0.0268327
Left Arm Collimator : 0.615527
Left LVDT HPM : 1661
Left LVDT VPM : 823
HacL_HPE1313A:0_Ch58 : -0.14209
HacL_HPE1313A:0_Ch55 : 22.4121
HacL_HPE1313A:0_Ch54 : -0.185547
HacL_alignROLL : 0.166831
HacL_alignPITCH : -0.115244
HacL_alignHPT : -0
Right Arm Collimator : 0.612061
Right LVDT HPM : -2403
Right LVDT VPM : 939
HacR_HPE1313A:0_Ch58 : -0.495605
HacR_HPE1313A:0_Ch55 : 21.0938
HacR_HPE1313A:0_Ch54 : -0.807617
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Wien angle : 80.233
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1866.3
Wien field : 53.472
Laser attenuation Hall A : 380
Laser power Hall A : 60
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : 0.40098
Target OTR y-position : 1.04903
Target OTR x-width : 0.864516
Target OTR y-width : 1.1631
Target OTR data valid flag : No
Target OTR In/Out : MaxPix is Bad
Arc OTR x-position : -1.94539
Arc OTR y-position : 0.244755
Arc OTR x-width : 3.33009
Arc OTR y-width : 1.96821
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0