Log entry time 01:40:23 on May24,2002
Entry number 4170
keyword=event type 2 was missing in data
Event type 2 was missing in data stream, because of a typo error in
prescale.dat. We noticed this started happening in run 1850.
Fixed as of run 1857. Implications are not too dire; the T2 are
useful for applying efficiency correction but these corrections are
probably stable.