• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 21:59:50 on May 30, 2002

    Entry number 4265

    keyword=End_of_Run_1024
    ****************************
     Run Number: 1024
     End of Run Comment:
    Run_type=cosmics,beam_energy=3.772,beam_raster=on,comment_text=cosmic,lower RA S1,S2 HV by 50V,daq_mode=Unbuff,kin_name=cosmic,leftarm_p=+2.979,leftarm_theta=23.665,rightarm_p=+0.756,rightarm_theta=63.876,target_type=empty
     
    
    PRESCALE FACTORS:ps1=1   ps2=1000   ps3=1   ps4=10   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS[0]: 315805       [+]: 154986       [-]: 154651       
    TIME  [0]: 278.502 mins  [+]: 136.541 mins  [-]: 136.540 mins  
    LIVE  [0]:  75.37%      [+]:  75.35%      [-]:  75.40%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 8.6/8.6  Hz   T2[0] : 0.9/878.6 Hz   T3[0] :11.1/11.1 Hz   T4[0] : 1.4/14.0 Hz   T5[0] : 3.1/3.1  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] : 8.6/8.6  Hz   T2[+] : 0.9/878.6 Hz   T3[+] :11.2/11.2 Hz   T4[+] : 1.4/14.0 Hz   T5[+] : 3.1/3.1  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] : 8.6/8.6  Hz   T2[-] : 0.9/878.6 Hz   T3[-] :11.1/11.1 Hz   T4[-] : 1.4/14.0 Hz   T5[-] : 3.0/3.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 143798/143798   T2[0] :  14681/14681236  T3[0] : 185900/185900   T4[0] :  23361/233618   T5[0] :  51005/51005    T8[0] :    261/17111171  
    T1[+] :  70456/70456    T2[+] :   7197/7197664  T3[+] :  91394/91394    T4[+] :  11470/114702   T5[+] :  25036/25036    T8[+] :    128/8389071  
    T1[-] :  70547/70547    T2[-] :   7197/7197562  T3[-] :  90837/90837    T4[-] :  11431/114318   T5[-] :  24968/24968    T8[-] :    128/8389033  
    
    AVERAGE CURRENT
    BCM x1 : 2.0916 uA  BCM x3 : 2.0968 uA  BCM x10: 2.0992 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    238.2 ppm     BCM u3 :    139.3 ppm     BCM u10:    106.7 ppm     
    BCM d1 :    284.1 ppm     BCM d3 :    140.5 ppm     BCM d10:    108.3 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.03496        BCM u3 [0]:0.03501        BCM u10[0]:0.03507        
    BCM u1 [+]:0.01714        BCM u3 [+]:0.01717        BCM u10[+]:0.0172         
    BCM u1 [-]:0.01713        BCM u3 [-]:0.01716        BCM u10[-]:0.01719        
    
    BCM d1 [0]:0.03494        BCM d3 [0]:0.03507        BCM d10[0]:0.03509        
    BCM d1 [+]:0.01713        BCM d3 [+]:0.0172         BCM d10[+]:0.01721        
    BCM d1 [-]:0.01712        BCM d3 [-]:0.01719        BCM d10[-]:0.0172         
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1024 at Thu May 30 21:59:14 EDT 2002
    Left Arm D1 momentum : 2.55
    Left Arm arm angle : 19.6507
    Right Arm D1 momentum : 2.55
    Right Arm arm angle : 19.6497
    Tiefenbach Hall A energy :
    Left Arm arm mispointing (HPT) : -0
    Right Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -2.83203
    Left Arm Bottom VDC Current : 3.4668
    Right Arm Top VDC Current :
    Right Arm Bottom VDC Current :
    Left Arm Q1 power supply current : 1918.49
    Left Arm Q1 momentum : 2.55006
    Left Arm Q1 gauss meter : -0.16211
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1097.83
    Left Arm Q2 momentum : 2.54954
    Left Arm Q2 gauss meter : 0.5787
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 880.15
    Left Arm D1 momentum : 2.55
    Left Arm D1 NMR : 0.94386
    Left Arm Q3 power supply current : 1015.24
    Left Arm Q3 momentum : 2.55009
    Left Arm Q3 gauss meter : -0.5079
    Left Arm Q3 power supply polarity : 1
    Right Arm Q1 power supply current : 1917.37
    Right Arm Q1 momentum : 2.54992
    Right Arm Q1 gauss meter : -0.04757
    Right Arm Q1 power supply polarity : 0
    Right Arm Q2 power supply current : 1097.44
    Right Arm Q2 momentum : 2.55001
    Right Arm Q2 gauss meter : 0.5763
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 901.203
    Right Arm D1 momentum : 2.55
    Right Arm D1 NMR : 0.946274
    Right Arm Q3 power supply current : 1014.52
    Right Arm Q3 momentum : 2.54963
    Right Arm Q3 gauss meter : 0.4553
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 4.2693
    Current on Unser monitor : 8.53899
    Current on Upstream bcm : 4.27676
    Current on Downstream bcm : 4.26184
    Upstream Cavity Coefficient : 77.4
    Downstream Cavity Coefficient : 79.06
    Current on IBC0L02 (source) :
    MBSY1c Hall A Beam energy :
    MBSY1c magnet current (amp) :
    MBSY1c Bdl :
    MBSY3c Hall C Beam energy :
    Tiefenbach Hall A energy :
    Tiefenbach Hall C energy :
    Delta(E)/E width (MV_AI_DXWID) :
    IPM1C12.XPOS :
    IPM1H04A.XPOS :
    IPM1H04A.YPOS :
    IPM1H04B.XPOS :
    IPM1H04B.YPOS :
    Left Arm Collimator : 0.368018
    Left LVDT HPM : 1287
    Left LVDT VPM : 604
    HacL_HPE1313A:0_Ch58 : -0.131836
    HacL_HPE1313A:0_Ch55 : 22.6562
    HacL_HPE1313A:0_Ch54 : -0.116699
    HacL_alignROLL : 0.230778
    HacL_alignPITCH : -0.126089
    HacL_alignHPT : -0
    Right Arm Collimator : 0.360449
    Right LVDT HPM : 1012
    Right LVDT VPM : !!WARNING!! The executable "caRepeater" couldnt be located because of errno = "No such file or directory" You may need to modify your PATH environment variable. Creating CA repeater with fork() system call. Repeater will inherit parents process name and resources. Duplicate resource consumption may occur. 126
    HacR_HPE1313A:0_Ch58 : -0.525391
    HacR_HPE1313A:0_Ch55 : 21.3867
    HacR_HPE1313A:0_Ch54 : -0.825195
    HacR_alignROLL : 0.466989
    HacR_alignPITCH : -0.489172
    HacR_alignHPT : -0
    Target OTR x-position : 0.135835
    Target OTR y-position : 0.916782
    Target OTR x-width : 0.260998
    Target OTR y-width : 0.255997
    Target OTR data valid flag : No
    Target OTR In/Out : MaxPix is Bad
    Arc OTR x-position : -1.94539
    Arc OTR y-position : 0.244755
    Arc OTR x-width : 3.33009
    Arc OTR y-width :
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    fan frequency loop 1 : 23.5
    fan frequency loop 2 : 27.5
    fan frequency loop 3 : 0
    Encoder position : 163854
    temperature loop 1 : 22
    temperature loop 1 : 22.23
    temperature loop 1 : 21.84
    temperature loop 2 : 19
    temperature loop 2 : 19
    temperature loop 2 : 19.2
    temperature loop 3 : 90.94
    temperature loop 3 : 75.27
    temperature loop 3 : 94.98
    pressure loop D2 : 26.7353
    pressure loop H2 : 25.1957
    Current Setpoint : 0
    Current Readback : 0