    User name a-onl

    Log entry time 18:30:00 on June 10, 2002

    Entry number 85788

    keyword=Start_Run_1395,Run_type=production,beam_energy=2.8423,beam_raster=on,comment_text=Q1_l50, 90uA, Production,daq_mode=Unbuff,kin_name=Q1D_l50,leftarm_p=2607.6,leftarm_theta=18.91,rightarm_p=461.6,rightarm_theta=82.67,target_type=15cm LD2
    Beginning-of-run EPICS data for Run Number 1395 at Mon Jun 10 18:29:48 EDT 2002
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ; PS1 for the Right spectrometer based on T1 defined by S1*S2
    ; PS2 for the Right spectrometer based on T2 defined by S1+S2
    ; PS3 for the Left spectrometer based on T3 defined by S1*S2
    ; PS4 for the Left spectrometer redundant trigger T4 S1*S0+S2*S0
    ; PS5 for coincidence of T1 and T3.
    ; PS7 irrelevant
    ; PS8 for pulser 
    ;ps1=1,ps2=1,ps3=65535,ps4=65535,ps5=65535,ps6=65535,ps7=65535,ps8=65535
    ps1=1380,ps2=1000,ps3=630,ps4=160,ps5=1,ps6=65535,ps7=65535,ps8=65535
    
    
    
    
     
    Left Arm Q1 power supply current : 1961.75
    Left Arm Q1 momentum : 2.60756
    Left Arm Q1 gauss meter : -0.16573
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1122.92
    Left Arm Q2 momentum : 2.60779
    Left Arm Q2 gauss meter : 0.5917
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 902.001
    Left Arm D1 momentum : 2.6076
    Left Arm D1 NMR : 0.965233
    Left Arm Q3 power supply current : 1038.19
    Left Arm Q3 momentum : 2.60775
    Left Arm Q3 gauss meter : -0.5195
    Left Arm Q3 power supply polarity : 1
    Right Arm Q1 power supply current : 347.06
    Right Arm Q1 momentum : 0.461556
    Right Arm Q1 gauss meter : 0.008814
    Right Arm Q1 power supply polarity : 1
    Right Arm Q2 power supply current : 198.477
    Right Arm Q2 momentum : 0.46118
    Right Arm Q2 gauss meter : -0.10537
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 154.811
    Right Arm D1 momentum : 0.461594
    Right Arm D1 NMR : 0.171292
    Right Arm Q3 power supply current : 183.556
    Right Arm Q3 momentum : 0.461302
    Right Arm Q3 gauss meter : -0.08294
    Right Arm Q3 power supply polarity : enabled
    Left Arm Top VDC Current : -1.36719
    Left Arm Bottom VDC Current : -7.27539
    Right Arm Top VDC Current :
    Right Arm Bottom VDC Current :
    Average current of the two cavities : 89.7452
    Current on Unser monitor : 93.9715
    Current on Upstream bcm : 89.6288
    Current on Downstream bcm : 89.8615
    Upstream Cavity Coefficient : 77.4
    Downstream Cavity Coefficient : 79.06
    Current on IBC0L02 (source) : 89.1932
    Tiefenbach Hall A energy : 2843.1
    Tiefenbach Hall C energy : 4705.71
    Delta(E)/E width (MV_AI_DXWID) : 0
    MBSY1c Hall A Beam energy : 2847.56
    MBSY3c Hall C Beam energy : 4720.11
    MBSY1c magnet current (amp) : 118.534
    MBSY1c Bdl : 710613
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Left Arm Arm Collimator : 0.870508
    Left LVDT HPM : 966
    Left LVDT VPM : 918
    HacL_HPE1313A:0_Ch58 : -0.140137
    HacL_HPE1313A:0_Ch55 : 23.7305
    HacL_HPE1313A:0_Ch54 : -0.0688477
    HacL_alignROLL : 0.276784
    HacL_alignPITCH : -0.141219
    HacL_alignHPT : -0
    Left Arm Angle Floor Angle : 19
    Left Arm Angle Vernier : 15.8
    Left Arm Scattering Angle : 18.9121
    Right Arm Arm Collimator : 0.862207
    Right LVDT HPM : -3010
    Right LVDT VPM : 1834
    HacR_HPE1313A:0_Ch58 : -0.467285
    HacR_HPE1313A:0_Ch55 : 22.5098
    HacR_HPE1313A:0_Ch54 : -0.743652
    HacR_alignROLL : 0.466989
    HacR_alignPITCH : -0.489172
    HacR_alignHPT : -0
    Right Arm Angle Floor Angle : 82.5
    Right Arm Angle Vernier : -4.5
    Right Arm Scattering Angle : 82.6711
    IPM1C12.XPOS : -0.0127479
    IPM1C12.YPOS : 0.0105728
    IPM1H04A.XPOS : 1.07261
    IPM1H04A.YPOS : 0.760609
    IPM1H04B.XPOS : 0.0142287
    IPM1H04B.YPOS : 0.0433486
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Target OTR x-position : 4.68786
    Target OTR y-position : 0.128201
    Target OTR x-width : 0.920671
    Target OTR y-width : 0.915805
    Target OTR data valid flag : No
    Target OTR In/Out : MaxPix is Bad
    Arc OTR x-position : -2.04243
    Arc OTR y-position : -0.173491
    Arc OTR x-width : 2.96956
    Arc OTR y-width : 3.03265
    Arc OTR data valid flag : No
    Arc OTR In/Out : Sources x.x
    Current Setpoint : 0
    Current Readback : 0
    fan frequency loop 1 : 59.5
    fan frequency loop 2 : 31
    fan frequency loop 3 : 0
    Encoder position : 6.27025e+06
    temperature loop 1 : 22
    temperature loop 1 : 22.23
    temperature loop 1 : 22.07
    temperature loop 2 : 19
    temperature loop 2 : 18.99
    temperature loop 2 : 19.14
    temperature loop 3 : 53.82
    temperature loop 3 : 53.5
    temperature loop 3 : 58.88
    pressure loop D2 : 28.2506
    pressure loop H2 : 27.0832