Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 13:23:46 on September 19, 2002
Entry number 87216
keyword=Start_Run_1074,Run_type=other,beam_energy=,beam_raster=off,comment_text=cosmic test, fpp on,daq_mode=Coinc (buffered),kin_name=,leftarm_p=0,leftarm_theta=16.1,rightarm_p=0,rightarm_theta=45.0,target_type=empty
Beginning-of-run EPICS data for Run Number 1074 at Thu Sep 19 13:21:51 EDT 2002
; (Integer!) prescale factors for each run, downloaded at prestart.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the Right spectrometer T1 defined by S1.and.S2
; PS2 for the Right spectrometer T2 defined by S0/S1/S2 majority
; PS3 for the Left spectrometer T3 defined by S1.and.S2
; PS4 for the Left spectrometer T4 defined by S0/S1/S2 majority
; PS5 for T5 coincidence trigger.
; PS8 for 1024 Hz pulser (keep this at <= 100)
; Trig 9 = 30 Hz, and you cannot prescale it.
ps1=1,ps2=4000,ps3=1,ps4=9999,ps5=1,ps6=65535,ps7=65535,ps8=65535
Left Arm Q1 power supply current :
Left Arm Q1 momentum : 0.499472
Left Arm Q1 gauss meter :
Left Arm Q1 power supply polarity :
Left Arm Q2 power supply current : 215.288
Left Arm Q2 momentum : 0.499972
Left Arm Q2 gauss meter :
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 154.731
Left Arm D1 momentum : 0.460146
Left Arm D1 NMR : 0.170495
Left Arm Q3 power supply current : 199.123
Left Arm Q3 momentum : 0.50016
Left Arm Q3 gauss meter :
Left Arm Q3 power supply polarity : enabled
Right Arm Q1 power supply current :
Right Arm Q1 momentum : 0.50002
Right Arm Q1 gauss meter : -0.00939
Right Arm Q1 power supply polarity :
Right Arm Q2 power supply current : 0.233802
Right Arm Q2 momentum : 0.000543262
Right Arm Q2 gauss meter : -0.0004007
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 65.8516
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.383577
Right Arm Q3 power supply current : 198.911
Right Arm Q3 momentum : 0.499891
Right Arm Q3 gauss meter : 0.08837
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : -2.73438
Left Arm Bottom VDC Current : -2.34375
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Average current of the two cavities : 0.0294427
Current on Unser monitor : 7.13448
Current on Upstream bcm : 0.0330386
Current on Downstream bcm : 0.0258516
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143517
Tiefenbach Hall A energy : 3057.69
Tiefenbach Hall C energy : 3057.26
Delta(E)/E width (MV_AI_DXWID) : 1.46632
MBSY1c Hall A Beam energy : 3062.42
MBSY3c Hall C Beam energy : 3065.55
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 764231
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Arm Collimator : 0.369482
Left LVDT HPM :
Left LVDT VPM :
HacL_HPE1313A:0_Ch58 : -0.193359
HacL_HPE1313A:0_Ch55 : 22.8027
HacL_HPE1313A:0_Ch54 : 0.0258789
HacL_alignROLL :
HacL_alignPITCH :
HacL_alignHPT :
Left Arm Angle Floor Angle :
Left Arm Angle Vernier :
Left Arm Scattering Angle :
Right Arm Arm Collimator : 0.361035
Right LVDT HPM : 5180
Right LVDT VPM : -1291
HacR_HPE1313A:0_Ch58 : -0.519043
HacR_HPE1313A:0_Ch55 : 22.0703
HacR_HPE1313A:0_Ch54 : -0.844238
HacR_alignROLL : 0
HacR_alignPITCH : 0
HacR_alignHPT : 0
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle : 0.195965
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 7.00001
Wien field : 0
Laser attenuation Hall A : 220
Laser power Hall A : 100
Half-wave plate (off=out) : !!WARNING!! The executable "caRepeater" couldnt be located because of errno = "No such file or directory" You may need to modify your PATH environment variable. Creating CA repeater with fork() system call. Repeater will inherit parents process name and resources. Duplicate resource consumption may occur. OUT
Beam Half-wave plate (off=out) : OUT
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern : Quartet
Target OTR x-position : -7.9589
Target OTR y-position : 7.73516
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : No
Target OTR In/Out : OTR is Out
Arc OTR x-position : 1.51311
Arc OTR y-position : 4.62166
Arc OTR x-width : 0.0422063
Arc OTR y-width : 0.0434544
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
fan frequency loop 1 : 0
fan frequency loop 2 : 29
fan frequency loop 3 : 24
Encoder position : 6.27024e+06
temperature loop 1 : 93.8
temperature loop 1 : 99.99
temperature loop 1 : 92.83
temperature loop 2 : 20.09
temperature loop 2 : 20.09
temperature loop 2 : 20.49
temperature loop 3 : 22.06
temperature loop 3 : 22.07
temperature loop 3 : 22.08
pressure loop D2 : 23.4043
pressure loop H2 : 24.8753
FPP HV 7.1.0 of chamber 1 : 0
FPP HV 7.1.1.of chamber 1 : 0
FPP HV 7.1.2 of chamber 1 : 12.7
FPP HV 7.1.3 of chamber 1 : 12.7
FPP HV 7.1.4 of chamber 1 : 0
FPP HV 7.1.5 of chamber 1 : 0
FPP HV 7.1.8 of chamber 2 : 0
FPP HV 7.1.9.of chamber 2 : 0
FPP HV 7.1.10 of chamber 2 : 15.1
FPP HV 7.1.11 of chamber 2 : 0
FPP HV 7.1.12 of chamber 2 : 0
FPP HV 7.1.13 of chamber 2 : 0
FPP HV 8.1.0 of chamber 3 : 0
FPP HV 8.1.1.of chamber 3 : 12
FPP HV 8.1.2 of chamber 3 : 0
FPP HV 8.1.3 of chamber 3 : 0
FPP HV 8.1.4 of chamber 3 : 0
FPP HV 8.1.5 of chamber 3 : 0
FPP HV 8.1.8 of chamber 4 : 10.8
FPP HV 8.1.9.of chamber 4 : 0
FPP HV 8.1.10 of chamber 4 : 0
FPP HV 8.1.11 of chamber 4 : 0
FPP HV 8.1.12 of chamber 4 : 0
FPP HV 8.1.13 of chamber 4 : 0