Main INDEX
Monthly INDEX
PREV
NEXT
User name gilman
Log entry time 09:49:03 on October 8,2002
Entry number 87629
keyword=rates
1) We think we understand why the singles rates are so large; it has largely
been neutrals leading to triggers but no tracks, probably most from the
radiator which is just at the edge of the acceptence.
2) We now are running at ~500 Hz T3s on the left arm. There appear to
be about 50 Hz of VDC travks, and 15 Hz of FPP scatters.
3) The physics replay should, to be clean, have cuts at Eg>1970 MeV,
to get rid of any gamma d --> p n pi0 backgrounds, and y_tgt < about 2.5 cm
or so, to get rid of things from the radiator and target end caps.
4) There is no way at this point to assess the flow diverter backgrounds.
Conclusion: it looks like we should be getting good analyzable data.