Main INDEX
Monthly INDEX
PREV
NEXT
User name R. Michaels
Log entry time 18:06:04 on October 8,2002
Entry number 87641
keyword=event type 140's had problems
I found that event type 140 (the "old" method of scaler data insertion) had
a problem since start of E00007 that data from scalers are out of phase with
respect to the documented data structure. It is recoverable, but you'll need to
ask me how. I fixed this for run 1234 and beyond. Meanwhile I think the "new"
scaler data in ROC10 are as advertised, and so is the end-of-run summary.
I worry that nobody is checking the scaler data.