Main INDEX
Monthly INDEX
PREV
NEXT
User name Suleiman
Log entry time 23:09:08 on October21,2002
Entry number 88699
keyword=Parity Target Boiling Test
Boiling Studies ala Parity Daq
DacNoise ON.
Raster 2.8X2.8 (set Value) (Measured 4X4)
15 cm LH2:
1926...30uA..OS=13..HG..HV1=-975..HV2=-1000
1927...30uA..OS=1..LG..HV1=-975..HV2=-1000 (lumi saturated)
1928...30uA..OS=1..LG..HV1=-900..HV2=-925
4 cm LH2
1929...100uA..OS=1..LG..HV1=-900..HV2=-925
1930...100uA..OS=13..HG..HV1=-900..HV2=-925
1931...100uA..OS=3..LG..HV1=-900..HV2=-925
1932...100uA..OS=1..LG..HV1=-900..HV2=-925
15 cm Al Dummy
1933...30uA..OS=1..LG..HV1=-900..HV2=-925
1934...30uA..OS=13..HG..HV1=-900..HV2=-925
1935...30uA..OS=13..HG..HV1=-950..HV2=-975
1936...30uA..OS=13..HG..HV1=-1000..HV2=-1025
15 cm LD2
1937...1uA..OS=13..HG..HV1=-1000..HV2=-1025
1938...1uA..OS=1..LG..HV1=-1000..HV2=-1025
1939...4uA..OS=1..LG..HV1=-1000..HV2=-1025