    User name a-onl

    Log entry time 21:30:18 on November 5, 2002

    Entry number 89702

    keyword=Start_Run_3021,Run_type=pointing,beam_energy=5.009,beam_raster=off,comment_text=pointing run at Q3_g40,daq_mode=Coinc (buffered),kin_name=Q3_g40,leftarm_p=3414.6,leftarm_theta=26.154,rightarm_p=2258.7,rightarm_theta=46.260,target_type=9-foil carbon
    Beginning-of-run EPICS data for Run Number 3021 at Tue Nov 5 21:29:48 EST 2002
    ; (Integer!) prescale factors for each run, downloaded at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ; PS1 for the Right spectrometer T1 defined by S1.and.S2
    ; PS2 for the Right spectrometer T2 defined by S0/S1/S2 majority
    ; PS3 for the Left spectrometer T3 defined by S1.and.S2
    ; PS4 for the Left spectrometer T4 defined by S0/S1/S2 majority
    ; PS5 for T5 coincidence trigger.
    ; PS8 for 1024 Hz pulser (keep this at <= 100)
    ; Trig 9 = 30 Hz, and you cannot prescale it.
     
    ps1=1,ps2=5,ps3=7,ps4=15,ps5=65535,ps6=65535,ps7=65535,ps8=65535
     
    Left Arm Q1 power supply current :
    Left Arm Q1 momentum : 3.4146
    Left Arm Q1 gauss meter :
    Left Arm Q1 power supply polarity :
    Left Arm Q2 power supply current : 1470.42
    Left Arm Q2 momentum : 3.41481
    Left Arm Q2 gauss meter :
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 1215.71
    Left Arm D1 momentum : 3.41461
    Left Arm D1 NMR : 1.26469
    Left Arm Q3 power supply current : 1359.37
    Left Arm Q3 momentum : 3.41449
    Left Arm Q3 gauss meter :
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 power supply current :
    Right Arm Q1 momentum : 2.25861
    Right Arm Q1 gauss meter : 0.04207
    Right Arm Q1 power supply polarity :
    Right Arm Q2 power supply current : 972.12
    Right Arm Q2 momentum : 2.25881
    Right Arm Q2 gauss meter : -0.5114
    Right Arm Q2 power supply polarity : disabled
    Right Arm D1 power supply current : 789.064
    Right Arm D1 momentum : 2.2587
    Right Arm D1 NMR : 0.838176
    Right Arm Q3 power supply current : 898.682
    Right Arm Q3 momentum : 2.25851
    Right Arm Q3 gauss meter : -0.4033
    Right Arm Q3 power supply polarity : enabled
    Left Arm Top VDC Current : 1.31836
    Left Arm Bottom VDC Current : 0
    Right Arm Top VDC Current :
    Right Arm Bottom VDC Current :
    Left Arm Top VDC voltage : 4.00244
    Left Arm Bottom VDC voltage : 3.99268
    Right Arm Top VDC voltage : 3.99365
    Right Arm Bottom VDC voltage : 3.99951
    Average current of the two cavities : 17.6338
    Current on Unser monitor : 11.7341
    Current on Upstream bcm : 17.7172
    Current on Downstream bcm : 17.5505
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 18.5525
    Tiefenbach Hall A energy : 5008.82
    Tiefenbach Hall C energy : 3028.11
    Delta(E)/E width (MV_AI_DXWID) : 12.0928
    MBSY1c Hall A Beam energy : 5019.53
    MBSY3c Hall C Beam energy : 3036.31
    MBSY1c magnet current (amp) : 209.525
    MBSY1c Bdl : 1.25263e+06
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Left Arm Arm Collimator : 0.871338
    Left LVDT HPM :
    Left LVDT VPM :
    HacL_HPE1313A:0_Ch58 : -0.157227
    HacL_HPE1313A:0_Ch55 : 22.9492
    HacL_HPE1313A:0_Ch54 : -0.215332
    HacL_alignROLL :
    HacL_alignPITCH :
    HacL_alignHPT :
    Left Arm Angle Floor Angle :
    Left Arm Angle Vernier :
    Left Arm Scattering Angle :
    Right Arm Arm Collimator : 0.863037
    Right LVDT HPM : 952
    Right LVDT VPM : -788
    HacR_HPE1313A:0_Ch58 : -0.530273
    HacR_HPE1313A:0_Ch55 : 21.4844
    HacR_HPE1313A:0_Ch54 : -0.90918
    HacR_alignROLL : 0.466989
    HacR_alignPITCH : -0.489172
    HacR_alignHPT : -0
    Right Arm Angle Floor Angle : 46
    Right Arm Angle Vernier : 10.9
    Right Arm Scattering Angle : 46.2598
    IPM1C12.XPOS : 0.563681
    IPM1C12.YPOS : 0.0434178
    IPM1H04A.XPOS : -0.148768
    IPM1H04A.YPOS : 0.629599
    IPM1H04B.XPOS : 0.131862
    IPM1H04B.YPOS : 0.221236
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle : -9.56139
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -221.08
    Wien field : 6.26
    Laser attenuation Hall A : 257
    Laser power Hall A : 62
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : 8 cycles
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : 8 cycles
    G0 Helicity Pattern : Quartet
    Target OTR x-position : 0.535127
    Target OTR y-position : 0.972837
    Target OTR x-width : 1.87595
    Target OTR y-width : 2.28672
    Target OTR data valid flag : No
    Target OTR In/Out : MaxPix is Bad
    Arc OTR x-position : -2.20052
    Arc OTR y-position : -2.71484
    Arc OTR x-width : 2.63498
    Arc OTR y-width : 1.31033
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    fan frequency loop 1 : 24
    fan frequency loop 2 : 74.5
    fan frequency loop 3 : 0
    Encoder position : 2.70817e+06
    temperature loop 1 : 19
    temperature loop 1 : 19.2
    temperature loop 1 : 92.83
    temperature loop 2 : 22
    temperature loop 2 : 21.99
    temperature loop 2 : 22.12
    temperature loop 3 : 94.98
    temperature loop 3 : 94.98
    temperature loop 3 : 94.98
    pressure loop D2 : 21.6602
    pressure loop H2 : 23.0701
    FPP HV 8.1.0 of chamber 3 : 1775.3
    FPP HV 8.1.1.of chamber 3 : 1775.3
    FPP HV 8.1.2 of chamber 3 : 1775.3
    FPP HV 8.1.3 of chamber 3 : 1775.3
    FPP HV 8.1.4 of chamber 3 : 1775.3
    FPP HV 8.1.5 of chamber 3 : 1775.3
    FPP HV 8.1.8 of chamber 4 : 1773.8
    FPP HV 8.1.9.of chamber 4 : 1773.8
    FPP HV 8.1.10 of chamber 4 : 1773.8
    FPP HV 8.1.11 of chamber 4 : 1773.8
    FPP HV 8.1.12 of chamber 4 : 1773.8
    FPP HV 8.1.13 of chamber 4 : 1773.8