keyword=Start_Run_3114,Run_type=production,beam_energy=5.009,beam_raster=on,comment_text=Hall C turns off Pockel Cell during this run (--> no polarized beam),daq_mode=Coinc (buffered),kin_name=Q3_j40,leftarm_p=3783,leftarm_theta=24.83,rightarm_p=1853.5,rightarm_theta=48.66,target_type=15cm LD2
Beginning-of-run EPICS data for Run Number 3114 at Tue Nov 12 07:02:28 EST 2002
; (Integer!) prescale factors for each run, downloaded at prestart.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the Right spectrometer T1 defined by S1.and.S2
; PS2 for the Right spectrometer T2 defined by S0/S1/S2 majority
; PS3 for the Left spectrometer T3 defined by S1.and.S2
; PS4 for the Left spectrometer T4 defined by S0/S1/S2 majority
; PS5 for T5 coincidence trigger.
; PS8 for 1024 Hz pulser (keep this at <= 100)
; Trig 9 = 30 Hz, and you cannot prescale it.
ps1=4,ps2=4,ps3=5,ps4=14,ps5=1,ps6=65535,ps7=65535,ps8=65535
Left Arm Q1 power supply current :
Left Arm Q1 momentum : 3.78303
Left Arm Q1 gauss meter :
Left Arm Q1 power supply polarity :
Left Arm Q2 power supply current : 1628.82
Left Arm Q2 momentum : 3.78268
Left Arm Q2 gauss meter :
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1387.75
Left Arm D1 momentum : 3.783
Left Arm D1 NMR : 1.40138
Left Arm Q3 power supply current : 1506.07
Left Arm Q3 momentum : 3.78296
Left Arm Q3 gauss meter :
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current :
Right Arm Q1 momentum : 1.85348
Right Arm Q1 gauss meter : 0.03459
Right Arm Q1 power supply polarity :
Right Arm Q2 power supply current : 797.538
Right Arm Q2 momentum : 1.85316
Right Arm Q2 gauss meter : -0.4199
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 639.332
Right Arm D1 momentum : 1.8535
Right Arm D1 NMR : 0.68781
Right Arm Q3 power supply current : 737.68
Right Arm Q3 momentum : 1.85389
Right Arm Q3 gauss meter : -0.3312
Right Arm Q3 power supply polarity : enabled
Left Arm Top VDC Current : 1.9043
Left Arm Bottom VDC Current : -1.26953
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Left Arm Top VDC voltage : 3.98584
Left Arm Bottom VDC voltage : 3.99463
Right Arm Top VDC voltage : 3.99268
Right Arm Bottom VDC voltage : 3.99854
Average current of the two cavities : 0.0331964
Current on Unser monitor : -6.18703
Current on Upstream bcm : 0.0360533
Current on Downstream bcm : 0.0297379
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
Tiefenbach Hall A energy : 5008.96
Tiefenbach Hall C energy : 3028.45
Delta(E)/E width (MV_AI_DXWID) : 0.804238
MBSY1c Hall A Beam energy : 5019.53
MBSY3c Hall C Beam energy : 3036.31
MBSY1c magnet current (amp) : 209.525
MBSY1c Bdl : 1.25263e+06
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Arm Collimator : 0.871533
Left LVDT HPM :
Left LVDT VPM :
HacL_HPE1313A:0_Ch58 : -0.138672
HacL_HPE1313A:0_Ch55 : 22.8027
HacL_HPE1313A:0_Ch54 : -0.174805
HacL_alignROLL :
HacL_alignPITCH :
HacL_alignHPT :
Left Arm Angle Floor Angle :
Left Arm Angle Vernier :
Left Arm Scattering Angle :
Right Arm Arm Collimator : 0.863086
Right LVDT HPM : 1059
Right LVDT VPM : -809
HacR_HPE1313A:0_Ch58 : -0.519531
HacR_HPE1313A:0_Ch55 : 21.3867
HacR_HPE1313A:0_Ch54 : -0.916016
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 48.5
Right Arm Angle Vernier : -6.5
Right Arm Scattering Angle : 48.6595
IPM1C12.XPOS : 0.0103239
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle : -9.56139
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -241.68
Wien field : 6.26
Laser attenuation Hall A : 120
Laser power Hall A : 62
Half-wave plate (off=out) : OFF
Beam Half-wave plate (off=out) : OUT
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern : Quartet
Target OTR x-position : 0.746515
Target OTR y-position : -0.0805034
Target OTR x-width : 1.91497
Target OTR y-width : 2.40102
Target OTR data valid flag : No
Target OTR In/Out : Current is Low
Arc OTR x-position : 1.27687
Arc OTR y-position : 4.62503
Arc OTR x-width : 0.0562157
Arc OTR y-width : 0.0440499
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
fan frequency loop 1 : 24
fan frequency loop 2 : 72.5
fan frequency loop 3 : 0
Encoder position : 5.53672e+06
temperature loop 1 : 19
temperature loop 1 : 19.19
temperature loop 1 : 92.83
temperature loop 2 : 22.01
temperature loop 2 : 22.01
temperature loop 2 : 22.14
temperature loop 3 : 94.98
temperature loop 3 : 94.98
temperature loop 3 : 94.98
pressure loop D2 : 22.1637
pressure loop H2 : 23.4653
FPP HV 8.1.0 of chamber 3 : 1775.3
FPP HV 8.1.1.of chamber 3 : 1775.3
FPP HV 8.1.2 of chamber 3 : 1775.3
FPP HV 8.1.3 of chamber 3 : 1775.3
FPP HV 8.1.4 of chamber 3 : 1775.3
FPP HV 8.1.5 of chamber 3 : 1775.3
FPP HV 8.1.8 of chamber 4 : 1773.8
FPP HV 8.1.9.of chamber 4 : 1773.8
FPP HV 8.1.10 of chamber 4 : 1773.8
FPP HV 8.1.11 of chamber 4 : 1773.8
FPP HV 8.1.12 of chamber 4 : 1773.8
FPP HV 8.1.13 of chamber 4 : 1773.8