Log entry time 11:26:21 on November 12, 2002
Entry number 89967
keyword=Start_Run_3119,Run_type=production,beam_energy=5.009,beam_raster=on,comment_text=Hall C turns off Pockel Cell during this run (--> no polarized beam),daq_mode=Coinc (buffered),kin_name=Q3_j40,leftarm_p=3783,leftarm_theta=24.83,rightarm_p=1853.5,rightarm_theta=48.66,target_type=15cm LD2
Beginning-of-run EPICS data for Run Number 3119 at Tue Nov 12 11:25:54 EST 2002
; (Integer!) prescale factors for each run, downloaded at prestart.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the Right spectrometer T1 defined by S1.and.S2
; PS2 for the Right spectrometer T2 defined by S0/S1/S2 majority
; PS3 for the Left spectrometer T3 defined by S1.and.S2
; PS4 for the Left spectrometer T4 defined by S0/S1/S2 majority
; PS5 for T5 coincidence trigger.
; PS8 for 1024 Hz pulser (keep this at <= 100)
; Trig 9 = 30 Hz, and you cannot prescale it.
ps1=4,ps2=4,ps3=5,ps4=14,ps5=1,ps6=65535,ps7=65535,ps8=65535
Left Arm Q1 power supply current :
Left Arm Q1 momentum : 3.78303
Left Arm Q1 gauss meter :
Left Arm Q1 power supply polarity :
Left Arm Q2 power supply current : 1628.76
Left Arm Q2 momentum : 3.78254
Left Arm Q2 gauss meter :
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1387.73
Left Arm D1 momentum : 3.78299
Left Arm D1 NMR : 1.40138
Left Arm Q3 power supply current : 1506.09
Left Arm Q3 momentum : 3.78301
Left Arm Q3 gauss meter :
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current :
Right Arm Q1 momentum : 1.85341
Right Arm Q1 gauss meter : 0.03461
Right Arm Q1 power supply polarity :
Right Arm Q2 power supply current : 797.857
Right Arm Q2 momentum : 1.8539
Right Arm Q2 gauss meter : -0.4199
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 639.339
Right Arm D1 momentum : 1.8535
Right Arm D1 NMR : 0.68781
Right Arm Q3 power supply current : 737.567
Right Arm Q3 momentum : 1.85361
Right Arm Q3 gauss meter : -0.3311
Right Arm Q3 power supply polarity : enabled
Left Arm Top VDC Current : 4.15039
Left Arm Bottom VDC Current : 2.09961
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Left Arm Top VDC voltage : 3.98096
Left Arm Bottom VDC voltage : 3.9917
Right Arm Top VDC voltage : 3.99316
Right Arm Bottom VDC voltage : 4.00244
Average current of the two cavities : 60.7108
Current on Unser monitor : 55.1717
Current on Upstream bcm : 60.8325
Current on Downstream bcm : 60.5892
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 78.0543
Tiefenbach Hall A energy : 5009.02
Tiefenbach Hall C energy : 3028.33
Delta(E)/E width (MV_AI_DXWID) : 0.141804
MBSY1c Hall A Beam energy : 5019.53
MBSY3c Hall C Beam energy : 3036.31
MBSY1c magnet current (amp) : 209.525
MBSY1c Bdl : 1.25263e+06
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Arm Collimator : 0.871484
Left LVDT HPM :
Left LVDT VPM :
HacL_HPE1313A:0_Ch58 : -0.137695
HacL_HPE1313A:0_Ch55 : 22.9004
HacL_HPE1313A:0_Ch54 : -0.174805
HacL_alignROLL :
HacL_alignPITCH :
HacL_alignHPT :
Left Arm Angle Floor Angle :
Left Arm Angle Vernier :
Left Arm Scattering Angle :
Right Arm Arm Collimator : 0.863086
Right LVDT HPM : 1068
Right LVDT VPM : -847
HacR_HPE1313A:0_Ch58 : -0.517578
HacR_HPE1313A:0_Ch55 : 21.5332
HacR_HPE1313A:0_Ch54 : -0.914551
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 48.5
Right Arm Angle Vernier : -6.5
Right Arm Scattering Angle : 48.6595
IPM1C12.XPOS : -0.00534008
IPM1C12.YPOS : 0.0344478
IPM1H04A.XPOS : -0.369913
IPM1H04A.YPOS : 0.482068
IPM1H04B.XPOS : -0.10138
IPM1H04B.YPOS : 0.0415141
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle : -9.56139
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -241.68
Wien field : 6.26
Laser attenuation Hall A : 359
Laser power Hall A : 62
Half-wave plate (off=out) : OFF
Beam Half-wave plate (off=out) : OUT
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern : Quartet
Target OTR x-position : 0.521653
Target OTR y-position : 1.19817
Target OTR x-width : 1.48187
Target OTR y-width : 1.80681
Target OTR data valid flag : Yes
Target OTR In/Out :
Arc OTR x-position : -1.9781
Arc OTR y-position : -0.530496
Arc OTR x-width : 2.89771
Arc OTR y-width : 2.64322
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
fan frequency loop 1 : 23.5
fan frequency loop 2 : 80
fan frequency loop 3 : 0
Encoder position : 5.53672e+06
temperature loop 1 : 19
temperature loop 1 : 19.2
temperature loop 1 : 92.83
temperature loop 2 : 22
temperature loop 2 : 21.99
temperature loop 2 : 22.32
temperature loop 3 : 94.98
temperature loop 3 : 94.98
temperature loop 3 : 94.98
pressure loop D2 : 22.1622
pressure loop H2 : 23.3722
FPP HV 8.1.0 of chamber 3 : 1776.2
FPP HV 8.1.1.of chamber 3 : 1776.2
FPP HV 8.1.2 of chamber 3 : 1776.2
FPP HV 8.1.3 of chamber 3 : 1776.2
FPP HV 8.1.4 of chamber 3 : 1776.2
FPP HV 8.1.5 of chamber 3 : 1776.2
FPP HV 8.1.8 of chamber 4 : 1773.8
FPP HV 8.1.9.of chamber 4 : 1773.8
FPP HV 8.1.10 of chamber 4 : 1773.8
FPP HV 8.1.11 of chamber 4 : 1773.8
FPP HV 8.1.12 of chamber 4 : 1773.8
FPP HV 8.1.13 of chamber 4 : 1773.8