Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 04:03:50 on November 13, 2002
Entry number 90011
keyword=End_of_Run_3136
****************************
Run Number: 3136
End of Run Comment:
Run_type=production,beam_energy=5.009,beam_raster=on,comment_text=production run,daq_mode=Coinc (buffered),kin_name=Q3_j40,leftarm_p=3783,leftarm_theta=24.83,rightarm_p=1853.5,rightarm_theta=48.66,target_type=15cm LD2
PRESCALE FACTORS:ps1=8 ps2=8 ps3=10 ps4=28 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 998598 [+]: 461008 [-]: 461334
TIME [0]: 54.264 mins [+]: 26.724 mins [-]: 26.725 mins
LIVE [0]: 98.14% [+]: 92.01% [-]: 92.06%
TRIGGER RATES: PRES/REAL
T1[0] :88.9/711.2 Hz T2[0] :45.9/367.1 Hz T3[0] :100.4/1004.4 Hz T4[0] :44.0/1232.3 Hz T5[0] : 3.3/3.3 Hz T8[0] : 0.0/1024.0 Hz
T1[+] :88.9/711.2 Hz T2[+] :45.9/366.8 Hz T3[+] :100.4/1004.2 Hz T4[+] :44.0/1232.4 Hz T5[+] : 3.3/3.3 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :88.9/711.1 Hz T2[-] :45.9/367.3 Hz T3[-] :100.5/1004.6 Hz T4[-] :44.0/1232.1 Hz T5[-] : 3.3/3.3 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 289436/2315491 T2[0] : 149385/1195083 T3[0] : 327007/3270075 T4[0] : 143292/4012200 T5[0] : 10657/10657 T8[0] : 50/3333995
T1[+] : 142549/1140394 T2[+] : 73519/588157 T3[+] : 161015/1610155 T4[+] : 70573/1976046 T5[+] : 5273/5273 T8[+] : 25/1641922
T1[-] : 142534/1140278 T2[-] : 73614/588913 T3[-] : 161082/1610826 T4[-] : 70558/1975626 T5[-] : 5224/5224 T8[-] : 25/1641993
AVERAGE CURRENT
BCM x1 : 80.6391uA BCM x3 : 80.5227uA BCM x10: 4.0134 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 22.42 ppm BCM u3 : 22.34 ppm BCM u10: 18.25 ppm
BCM d1 : 22.33 ppm BCM d3 : 22.75 ppm BCM d10: 15.35 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:0.2639 BCM u3 [0]:0.2636 BCM u10[0]:-0.1308
BCM u1 [+]:0.1299 BCM u3 [+]:0.1298 BCM u10[+]:0.1055
BCM u1 [-]:0.1299 BCM u3 [-]:0.1298 BCM u10[-]:0.1055
BCM d1 [0]:0.2612 BCM d3 [0]:0.2607 BCM d10[0]:0.157
BCM d1 [+]:0.1287 BCM d3 [+]:0.1284 BCM d10[+]:0.0773
BCM d1 [-]:0.1287 BCM d3 [-]:0.1284 BCM d10[-]:0.0773
****************************
End-of-run EPICS data for Run Number 3136 at Wed Nov 13 04:01:15 EST 2002
Left Arm D1 momentum : 3.783
Left Arm arm angle : 24.8302
Right Arm D1 momentum : 1.8535
Right Arm arm angle : 48.6595
Tiefenbach Hall A energy : 5008.95
Left Arm arm mispointing (HPT) :
Right Arm arm mispointing (HPT) : -0
Left Arm Top VDC Current : -3.32031
Left Arm Bottom VDC Current : -1.95312
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Left Arm Q1 power supply current :
Left Arm Q1 momentum : 3.78303
Left Arm Q1 gauss meter :
Left Arm Q1 power supply polarity :
Left Arm Q2 power supply current : 1628.81
Left Arm Q2 momentum : 3.78266
Left Arm Q2 gauss meter :
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1387.74
Left Arm D1 momentum : 3.78301
Left Arm D1 NMR : 1.40139
Left Arm Q3 power supply current : 1506.09
Left Arm Q3 momentum : 3.78302
Left Arm Q3 gauss meter :
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current :
Right Arm Q1 momentum : 1.85348
Right Arm Q1 gauss meter : 0.03459
Right Arm Q1 power supply polarity :
Right Arm Q2 power supply current : 797.763
Right Arm Q2 momentum : 1.85368
Right Arm Q2 gauss meter : -0.42
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 639.339
Right Arm D1 momentum : 1.8535
Right Arm D1 NMR : 0.68781
Right Arm Q3 power supply current : 737.591
Right Arm Q3 momentum : 1.85367
Right Arm Q3 gauss meter : -0.3312
Right Arm Q3 power supply polarity : enabled
Average current of the two cavities : 98.7039
Current on Unser monitor : 91.8592
Current on Upstream bcm : 99.4357
Current on Downstream bcm : 97.9722
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 115.737
MBSY1c Hall A Beam energy : 5019.53
MBSY1c magnet current (amp) : 209.525
MBSY1c Bdl : 1.25263e+06
MBSY3c Hall C Beam energy : 3036.31
Tiefenbach Hall A energy : 5008.95
Tiefenbach Hall C energy : 3028.2
Delta(E)/E width (MV_AI_DXWID) : 0.266691
IPM1C12.XPOS : 0.000112206
IPM1H04A.XPOS : -0.386687
IPM1H04A.YPOS : 0.408847
IPM1H04B.XPOS : -0.0424364
IPM1H04B.YPOS : 0.00660771
Left Arm Collimator : 0.871436
Left LVDT HPM :
Left LVDT VPM :
HacL_HPE1313A:0_Ch58 : -0.13623
HacL_HPE1313A:0_Ch55 : 22.9004
HacL_HPE1313A:0_Ch54 : -0.17627
HacL_alignROLL :
HacL_alignPITCH :
HacL_alignHPT :
Right Arm Collimator : 0.863037
Right LVDT HPM : 1077
Right LVDT VPM : -867
HacR_HPE1313A:0_Ch58 : -0.518555
HacR_HPE1313A:0_Ch55 : 21.4844
HacR_HPE1313A:0_Ch54 : -0.915039
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Wien angle : -9.56139
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -241.68
Wien field : 6.26
Laser attenuation Hall A : 378
Laser power Hall A : 62
Half-wave plate (off=out) : OFF
Beam Half-wave plate (off=out) : OUT
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern : Quartet
Target OTR x-position : 0.595047
Target OTR y-position : 1.30921
Target OTR x-width : 1.42813
Target OTR y-width : 1.67346
Target OTR data valid flag : Yes
Target OTR In/Out : !!WARNING!! The executable "caRepeater" couldnt be located because of errno = "No such file or directory" You may need to modify your PATH environment variable. Creating CA repeater with fork() system call. Repeater will inherit parents process name and resources. Duplicate resource consumption may occur.
Arc OTR x-position : 1.26783
Arc OTR y-position : 4.62341
Arc OTR x-width : 0.056805
Arc OTR y-width : 0.0445986
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
fan frequency loop 1 : 24
fan frequency loop 2 : 70.5
fan frequency loop 3 : 0
Encoder position : 5.53672e+06
temperature loop 1 : 19
temperature loop 1 : 19.2
temperature loop 1 : 92.83
temperature loop 2 : 22
temperature loop 2 : 22
temperature loop 2 : 22.35
temperature loop 3 : 94.98
temperature loop 3 : 94.98
temperature loop 3 : 94.98
pressure loop D2 : 21.6632
pressure loop H2 : 22.9404
FPP HV 8.1.0 of chamber 3 : 1776.2
FPP HV 8.1.1.of chamber 3 : 1776.2
FPP HV 8.1.2 of chamber 3 : 1776.2
FPP HV 8.1.3 of chamber 3 : 1776.2
FPP HV 8.1.4 of chamber 3 : 1776.2
FPP HV 8.1.5 of chamber 3 : 1776.2
FPP HV 8.1.8 of chamber 4 : 1773.8
FPP HV 8.1.9.of chamber 4 : 1773.8
FPP HV 8.1.10 of chamber 4 : 1773.8
FPP HV 8.1.11 of chamber 4 : 1773.8
FPP HV 8.1.12 of chamber 4 : 1773.8
FPP HV 8.1.13 of chamber 4 : 1773.8