User name rom/moffit/kdp
Log entry time 10:04:33 on November15,2002
Entry number 90134
Followups:
keyword=missing cable replaced, iocse9 (bpm12)
The parity DAQ has had trouble recently with the bpm at the most dispersive point in
the arc, bpm 12. We examined the appropriate crate (iocse9) and found that the
sample and hold card reading out this bpm did not have a front panel serial
connection from the previous sample-and-hold card. (There are two front panel
connectors, and the first sample-and-hold should start a daisy-chain to all later
sample-and-hold cards in the crate, on the upper connector.)
Anyhoo, we used three short twisted-pair cables to replace the missing ribbon cable.
Hopefully this fixes our problem, and we don't expect this to impact any other
function in that crate.