• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 04:03:49 on January 6, 2003

    Entry number 90529

    keyword=Start_Run_1068,Run_type=other,beam_energy=0,beam_raster=off,comment_text=beam tuning,daq_mode=both HRS daq,kin_name=,leftarm_p=N/A,leftarm_theta=N/A,rightarm_p=N/A,rightarm_theta=N/A,target_halfwaveplate=out,target_name=duke,target_polarization=0,target_type=Empty
    Beginning-of-run EPICS data for Run Number 1068 at Mon Jan 6 04:03:23 EST 2003
    ; RIGHT SPECTROMETER  on adaql2 computer on a-onl account.
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 to measure efficiency
    ; PS1 for the Right spectrometer T1 defined by S1.and.S2
    ; PS2 for the Right spectrometer T2 defined by Cerenkov/S1/S2 majority
    ; PS8 for 1024 Hz pulser (keep this at <= 100)
    ; Trig 9 = 30 Hz, and you cannot prescale it.
     
    ps1=1,ps2=1,ps3=5000,ps4=5000,ps5=1,ps6=65535,ps7=65535,ps8=65535
    
     
    Right Arm Q1 power supply current :
    Right Arm Q1 momentum : 1.05601
    Right Arm Q1 gauss meter : -0.019762
    Right Arm Q1 power supply polarity :
    Right Arm Q2 power supply current : 454.36
    Right Arm Q2 momentum : 1.05578
    Right Arm Q2 gauss meter : !!WARNING!! The executable "caRepeater" couldnt be located because of errno = "No such file or directory" You may need to modify your PATH environment variable. Creating CA repeater with fork() system call. Repeater will inherit parents process name and resources. Duplicate resource consumption may occur. 0.2388
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 363.095
    Right Arm D1 momentum : 1.05601
    Right Arm D1 NMR : 0.391872
    Right Arm Q3 power supply current : 420.409
    Right Arm Q3 momentum : 1.05655
    Right Arm Q3 gauss meter : 0.18827
    Right Arm Q3 power supply polarity : disabled
    Right Arm Top VDC Current :
    Right Arm Bottom VDC Current :
    Right Arm Top VDC voltage : 3.99414
    Right Arm Bottom VDC voltage : 4.00928
    Average current of the two cavities : 4.91829
    Current on Unser monitor : -10.5016
    Current on Upstream bcm : 4.93486
    Current on Downstream bcm : 4.90172
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78
    Current on IBC0L02 (source) : 4.98313
    Tiefenbach Hall A energy : 5008.97
    Tiefenbach Hall C energy : 3028.2
    Delta(E)/E width (MV_AI_DXWID) : 6.15864
    MBSY1c Hall A Beam energy : 1046.86
    MBSY3c Hall C Beam energy : 3036.3
    MBSY1c magnet current (amp) : 43.3083
    MBSY1c Bdl : 261245
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Right Arm Arm Collimator : 0.862988
    Right LVDT HPM : 3217
    Right LVDT VPM : 3863
    HacR_HPE1313A:0_Ch58 : -0.526367
    HacR_HPE1313A:0_Ch55 : 22.168
    HacR_HPE1313A:0_Ch54 : -0.852539
    HacR_alignROLL : 0
    HacR_alignPITCH : 0
    HacR_alignHPT : 0
    Right Arm Angle Floor Angle : 0
    Right Arm Angle Vernier : 0
    Right Arm Scattering Angle : 0
    IPM1C12.XPOS : -1.23062
    IPM1C12.YPOS : 0.0492475
    IPM1H04A.XPOS : 0.0202397
    IPM1H04A.YPOS : -0.119646 !!WARNING!! The executable "caRepeater" couldnt be located because of errno = "No such file or directory" You may need to modify your PATH environment variable. Creating CA repeater with fork() system call. Repeater will inherit parents process name and resources. Duplicate resource consumption may occur.
    IPM1H04B.XPOS : 0.0175282
    IPM1H04B.YPOS : -0.220586
    Survey X offset bpmA : 0
    Survey Y offset bpmA : 0
    Survey X offset bpmB : 0
    Survey Y offset bpmB : 0
    Wien angle : 10.1958
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 237.18
    Wien field : 6.684
    Laser attenuation Hall A : 170
    Laser power Hall A : 65
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : 8 cycles
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : 8 cycles
    G0 Helicity Pattern : Quartet
    Target OTR x-position : -0.736997
    Target OTR y-position : -2.23144
    Target OTR x-width : 2.78754
    Target OTR y-width : 2.39635
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    Arc OTR x-position : -2.06356
    Arc OTR y-position : -0.136763
    Arc OTR x-width : 2.96598
    Arc OTR y-width : 3.03807
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    FPP HV 8.1.13 of chamber 4 : 23.5