NEXT
User name a-onl
Log entry time 11:50:12 on January 6, 2003
Entry number 90572
keyword=End_of_Run_1081
****************************
Run Number: 1081
End of Run Comment:
Run_type=other,beam_energy=1.056,beam_raster=off,comment_text=,daq_mode=both HRS daq,kin_name=,leftarm_p=1.056,leftarm_theta=16,rightarm_p=1.056,rightarm_theta=16,target_halfwaveplate=out,target_name=duke,target_polarization=0,target_type=BeO Carbon foils
ur
PRESCALE FACTORS:ps1=1 ps2=1 ps3=5000 ps4=5000 ps5=1 ps6=65535 ps7=65535 ps8=65535
EVENTS[0]: 851 [+]: 134 [-]: 140
TIME [0]: 0.318 mins [+]: 0.151 mins [-]: 0.151 mins
LIVE [0]: 98.95% [+]: 33.09% [-]: 33.90%
TRIGGER RATES: PRES/REAL
T1[0] : 9.5/9.5 Hz T2[0] : 5.6/5.6 Hz T8[0] : 0.0/1024.0 Hz
T1[+] : 9.2/9.2 Hz T2[+] : 5.6/5.6 Hz T8[+] : 0.0/1024.0 Hz
T1[-] :10.1/10.1 Hz T2[-] : 5.4/5.4 Hz T8[-] : 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 181/181 T2[0] : 107/107 T8[0] : 0/19540
T1[+] : 83/83 T2[+] : 51/51 T8[+] : 0/9253
T1[-] : 92/92 T2[-] : 49/49 T8[-] : 0/9285
AVERAGE CURRENT
BCM x1 : 0.1288 uA BCM x3 : 0.1188 uA BCM x10: 0.1140 uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 3207 ppm BCM u3 : 2372 ppm BCM u10: 1038 ppm
BCM d1 : 422.8 ppm BCM d3 : -1828 ppm BCM d10: -241.2 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:2.554E-06 BCM u3 [0]:2.441E-06 BCM u10[0]:2.307E-06
BCM u1 [+]:1.214E-06 BCM u3 [+]:1.159E-06 BCM u10[+]:1.093E-06
BCM u1 [-]:1.21E-06 BCM u3 [-]:1.157E-06 BCM u10[-]:1.095E-06
BCM d1 [0]:2.361E-06 BCM d3 [0]:2.094E-06 BCM d10[0]:2.045E-06
BCM d1 [+]:1.11E-06 BCM d3 [+]:9.895E-07 BCM d10[+]:9.688E-07
BCM d1 [-]:1.113E-06 BCM d3 [-]:9.966E-07 BCM d10[-]:9.726E-07
****************************
End-of-run EPICS data for Run Number 1081 at Mon Jan 6 11:32:24 EST 2003
Left Arm D1 momentum : 1.05601
Left Arm arm angle :
Right Arm D1 momentum : 1.056
Right Arm arm angle : 15.9953
Tiefenbach Hall A energy : 5008.97
Left Arm arm mispointing (HPT) :
Right Arm arm mispointing (HPT) : -0
Left Arm Top VDC Current : -0.976562
Left Arm Bottom VDC Current : -1.5625
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Left Arm Q1 power supply current :
Left Arm Q1 momentum : 1.05602
Left Arm Q1 gauss meter :
Left Arm Q1 power supply polarity :
Left Arm Q2 power supply current : 454.504
Left Arm Q2 momentum : 1.05551
Left Arm Q2 gauss meter :
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 353.311
Left Arm D1 momentum : 1.05602
Left Arm D1 NMR : 0.390955
Left Arm Q3 power supply current : 420.382
Left Arm Q3 momentum : 1.05592
Left Arm Q3 gauss meter :
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current :
Right Arm Q1 momentum : 1.05608
Right Arm Q1 gauss meter : -0.019763
Right Arm Q1 power supply polarity :
Right Arm Q2 power supply current : 454.513
Right Arm Q2 momentum : 1.0561
Right Arm Q2 gauss meter : 0.2388
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 363.094
Right Arm D1 momentum : 1.056
Right Arm D1 NMR : 0.391869
Right Arm Q3 power supply current : 420.138
Right Arm Q3 momentum : 1.05587
Right Arm Q3 gauss meter : 0.18824
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 0.22283
Current on Unser monitor : -15.5178
Current on Upstream bcm : 0.235151
Current on Downstream bcm :
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78
Current on IBC0L02 (source) : 0.00143682
MBSY1c Hall A Beam energy : 1046.86
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 261245
MBSY3c Hall C Beam energy : 3036.3
Tiefenbach Hall A energy : 5008.97
Tiefenbach Hall C energy : 3028.2
Delta(E)/E width (MV_AI_DXWID) : 6.80676
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Left Arm Collimator : 0.871338
Left LVDT HPM :
Left LVDT VPM :
HacL_HPE1313A:0_Ch58 : -0.170898
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : -0.00341797
HacL_alignROLL :
HacL_alignPITCH :
HacL_alignHPT :
Right Arm Collimator : 0.862939
Right LVDT HPM : 3218
Right LVDT VPM : 3862
HacR_HPE1313A:0_Ch58 : -0.526855
HacR_HPE1313A:0_Ch55 : 22.0215
HacR_HPE1313A:0_Ch54 : -0.854492
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Wien angle : 10.1958
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 237.18
Wien field : 6.684
Laser attenuation Hall A : 120
Laser power Hall A : 66
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern : Quartet
Target OTR x-position : -0.238616
Target OTR y-position : -2.42367
Target OTR x-width : 2.85277
Target OTR y-width : 2.14983
Target OTR data valid flag : No
Target OTR In/Out : Current is Low
Arc OTR x-position : -2.06286
Arc OTR y-position : -0.137174
Arc OTR x-width : 2.97173
Arc OTR y-width : 3.04193
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Polarized 3He Target RTD #1 : 45.5078
Polarized 3He Target RTD #2 : 43.6328
Polarized 3He Target RTD #3 : 45.6445
Polarized 3He Target RTD #4 : !!WARNING!! The executable "caRepeater" couldnt be located because of errno = "No such file or directory" You may need to modify your PATH environment variable. Creating CA repeater with fork() system call. Repeater will inherit parents process name and resources. Duplicate resource consumption may occur. 41.6309
Polarized 3He Target RTD #5 : 40.4395
Polarized 3He Target RTD #6 : 192.246
Polarized 3He Target RTD #7 : 171.035
Polarized 3He Ref. Cell RTD #8 : 25.166
Polarized 3He Ref. Cell RTD #9 : 40.1855
Polarized 3He Ref. Cell RTD #10 : 0.761719
Polarized 3He Target Ref. Cell Gas Pres. : -17.359
Polarized 3He Target Ref. Cell Sys.Vac. : 27.8908
Polarized 3He Target Cooling Jet : 56.1768
Polarized 3He Target OVEN RTD : 169.9
Polarized 3He Target OVEN SP1 SET : 170
Polarized 3He Target OVEN SP1 : 170
Polarized 3He Target OVEN AL1 SET : 0
Polarized 3He Target OVEN AL1 : 200
Polarized 3He Target OVEN AL1 STATUS : enabled
Polarized 3He Target Half-Wave Plate DIST: 1.2e+06
Polarized 3He Target Half-Wave Plate STAT: 1200000
Polarized 3He Target Position (PA) : 198.219
Polarized 3He Target Position (POS) : Pick-up Coils
Polarized 3He Target Position (DA) : 198.219
Polarized 3He Target Position (SS9) : Axis is OK
Polarized 3He Target Position (SA10) : 0
Polarized 3He Target Position (SA9) : 0
Polarized 3He Laser#1 State : 0
Polarized 3He Laser#1 Current : 35.6
Polarized 3He Laser#1 Temperature : 18.6
Polarized 3He Laser#2 State : 0
Polarized 3He Laser#2 Current : 41.4
Polarized 3He Laser#2 Temperature : 9.9
Polarized 3He Laser#3 State : 0
Polarized 3He Laser#3 Current : 38.1
Polarized 3He Laser#3 Temperature : 11.5
Polarized 3He Laser#4 State : 0
Polarized 3He Laser#4 Current : 37.5
Polarized 3He Laser#4 Temperature : 17.5
Polarized 3He Laser#5 State : 2
Polarized 3He Laser#5 Current : 39.3
Polarized 3He Laser#5 Temperature : 13.1
Polarized 3He Laser#6 State : 2
Polarized 3He Laser#6 Current : 40
Polarized 3He Laser#6 Temperature : 9.2
Polarized 3He Laser#7 State : 2
Polarized 3He Laser#7 Current : 38.8
Polarized 3He Laser#7 Temperature : 9.7
Polarized 3He Coil Current Longitudinal : 0
Polarized 3He Coil Current Transverse : 0