    keyword=BCM offset problem fixed

    There was a problem of BCM offset more trhan 0.2 microA (cavity readout noise
    was about 3 mV for both upstream and down stream). Arun contacted John Musson.
    John fixed the problem: the signal shield was initiallyconnected to the Guard and by
    switching it to Ground, the noise reduced to about 0.2 mV and BCM reading is now
    0.015 microA.