NEXT
User name a-onl
Log entry time 03:57:00 on January 7, 2003
Entry number 90687
keyword=End_of_Run_1122
****************************
Run Number: 1122
End of Run Comment:
Run_type=other,beam_energy=1.045,beam_raster=off,comment_text=DAQ tests,daq_mode=one HRS daq,kin_name=,leftarm_p=1.056,leftarm_theta=16,rightarm_p=1.056,rightarm_theta=16,target_halfwaveplate=out,target_name=duke,target_polarization=0,target_type=BeO Carbon foils
PRESCALE FACTORS:ps1=42 ps2=1 ps3=9999 ps4=9999 ps5=65535 ps6=65535 ps7=65535 ps8=1
EVENTS[0]: 122899 [+]: 58846 [-]: 58779
TIME [0]: 3.405 mins [+]: 1.672 mins [-]: 1.672 mins
LIVE [0]: 56.77% [+]: 55.36% [-]: 55.33%
TRIGGER RATES: PRES/REAL
T1[0] : 0.2/9.8 Hz T2[0] : 5.2/5.2 Hz T8[0] :1024.0/1024.0 Hz
T1[+] : 0.2/9.6 Hz T2[+] : 5.4/5.4 Hz T8[+] :1024.0/1024.0 Hz
T1[-] : 0.2/9.9 Hz T2[-] : 5.0/5.0 Hz T8[-] :1024.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] : 47/1997 T2[0] : 1066/1066 T8[0] : 209230/209230
T1[+] : 22/963 T2[+] : 541/541 T8[+] : 102734/102734
T1[-] : 23/990 T2[-] : 503/503 T8[-] : 102701/102701
AVERAGE CURRENT
BCM x1 : 0.0055 uA BCM x3 : -0.0099uA BCM x10: -0.0173uA
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 :-1.774E+04 ppm BCM u3 : 1E+39 ppm BCM u10: 1E+39 ppm
BCM d1 : -5009 ppm BCM d3 : 1E+39 ppm BCM d10: 1E+39 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0]:5.293E-07 BCM u3 [0]:-2.56E-06 BCM u10[0]:-4.8E-06
BCM u1 [+]:2.505E-07 BCM u3 [+]:-1.256E-06 BCM u10[+]:-2.355E-06
BCM u1 [-]:2.595E-07 BCM u3 [-]:-1.254E-06 BCM u10[-]:-2.359E-06
BCM d1 [0]:1.732E-06 BCM d3 [0]:-1.486E-06 BCM d10[0]:-2.254E-06
BCM d1 [+]:8.437E-07 BCM d3 [+]:-7.33E-07 BCM d10[+]:-1.109E-06
BCM d1 [-]:8.519E-07 BCM d3 [-]:-7.272E-07 BCM d10[-]:-1.108E-06
****************************
End-of-run EPICS data for Run Number 1122 at Tue Jan 7 03:55:10 EST 2003
Left Arm D1 momentum : 1.042
Left Arm arm angle : 16.0054
Right Arm D1 momentum : 1.042
Right Arm arm angle : 15.9953
Tiefenbach Hall A energy : 5008.97
Left Arm arm mispointing (HPT) :
Right Arm arm mispointing (HPT) : -0
Left Arm Top VDC Current : 1.5625
Left Arm Bottom VDC Current : 1.95312
Right Arm Top VDC Current :
Right Arm Bottom VDC Current :
Left Arm Q1 power supply current :
Left Arm Q1 momentum : 1.04203
Left Arm Q1 gauss meter :
Left Arm Q1 power supply polarity :
Left Arm Q2 power supply current : 448.59
Left Arm Q2 momentum : 1.04178
Left Arm Q2 gauss meter :
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 348.612
Left Arm D1 momentum : 1.042
Left Arm D1 NMR : 0.38577
Left Arm Q3 power supply current : 414.905
Left Arm Q3 momentum : 1.04216
Left Arm Q3 gauss meter :
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current :
Right Arm Q1 momentum : 1.04194
Right Arm Q1 gauss meter : -0.019486
Right Arm Q1 power supply polarity :
Right Arm Q2 power supply current : 745.414
Right Arm Q2 momentum : 1.73204
Right Arm Q2 gauss meter : 0.3878
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 358.128
Right Arm D1 momentum : 1.042
Right Arm D1 NMR : 0.386673
Right Arm Q3 power supply current : 414.595
Right Arm Q3 momentum : 1.04194
Right Arm Q3 gauss meter : 0.18577
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 0.0149015
Current on Unser monitor : -16.4532
Current on Upstream bcm : 0.0144233
Current on Downstream bcm : 0.0153796
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 10.9737
MBSY1c Hall A Beam energy : 1046.86
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 261245
MBSY3c Hall C Beam energy : 3036.3
Tiefenbach Hall A energy : 5008.97
Tiefenbach Hall C energy : 3028.2
Delta(E)/E width (MV_AI_DXWID) : 1.55059
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Left Arm Collimator : 0.871436
Left LVDT HPM :
Left LVDT VPM :
HacL_HPE1313A:0_Ch58 : -0.170898
HacL_HPE1313A:0_Ch55 : 22.9004
HacL_HPE1313A:0_Ch54 : -0.00390625
HacL_alignROLL :
HacL_alignPITCH :
HacL_alignHPT :
Right Arm Collimator : 0.863086
Right LVDT HPM : 3215
Right LVDT VPM : 3861
HacR_HPE1313A:0_Ch58 : -0.524902
HacR_HPE1313A:0_Ch55 : 21.7285
HacR_HPE1313A:0_Ch54 : -0.858887
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0 !!WARNING!! The executable "caRepeater" couldnt be located because of errno = "No such file or directory" You may need to modify your PATH environment variable. Creating CA repeater with fork() system call. Repeater will inherit parents process name and resources. Duplicate resource consumption may occur.
Wien angle : 10.1958
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 237.18
Wien field : 6.684
Laser attenuation Hall A : 100
Laser power Hall A : 66
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern : Quartet
Target OTR x-position : !!WARNING!! The executable "caRepeater" couldnt be located because of errno = "No such file or directory" You may need to modify your PATH environment variable. Creating CA repeater with fork() system call. Repeater will inherit parents process name and resources. Duplicate resource consumption may occur. 2.03237
Target OTR y-position : 0.693824
Target OTR x-width : 1.1049
Target OTR y-width : 0.644864
Target OTR data valid flag : No
Target OTR In/Out : Current is Low
Arc OTR x-position : -1.94379
Arc OTR y-position : -0.389935
Arc OTR x-width : 3.01652
Arc OTR y-width : 3.04799
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Polarized 3He Target RTD #1 : 45.8105
Polarized 3He Target RTD #2 : 43.7988
Polarized 3He Target RTD #3 : 45.5371
Polarized 3He Target RTD #4 : 41.1719
Polarized 3He Target RTD #5 : 40.1465
Polarized 3He Target RTD #6 : 171.152
Polarized 3He Target RTD #7 : 193.125
Polarized 3He Ref. Cell RTD #8 : 25.2441
Polarized 3He Ref. Cell RTD #9 : 44.9805
Polarized 3He Ref. Cell RTD #10 : 0
Polarized 3He Target Ref. Cell Gas Pres. : -8.83485
Polarized 3He Target Ref. Cell Sys.Vac. : 29.5182
Polarized 3He Target Cooling Jet : 58.0261
Polarized 3He Target OVEN RTD : 170.2
Polarized 3He Target OVEN SP1 SET : 0
Polarized 3He Target OVEN SP1 : 0
Polarized 3He Target OVEN AL1 SET : 0
Polarized 3He Target OVEN AL1 : 0
Polarized 3He Target OVEN AL1 STATUS : enabled
Polarized 3He Target Half-Wave Plate DIST: 1.2e+06
Polarized 3He Target Half-Wave Plate STAT: 1200000
Polarized 3He Target Position (PA) : 198.219
Polarized 3He Target Position (POS) : Pick-up Coils
Polarized 3He Target Position (DA) : 198.219
Polarized 3He Target Position (SS9) : Axis is OK
Polarized 3He Target Position (SA10) : 0
Polarized 3He Target Position (SA9) : 0
Polarized 3He Laser#1 State : 0
Polarized 3He Laser#1 Current : 35.6
Polarized 3He Laser#1 Temperature : 18.6
Polarized 3He Laser#2 State : 0
Polarized 3He Laser#2 Current : 41.4
Polarized 3He Laser#2 Temperature : 9.9
Polarized 3He Laser#3 State : 0
Polarized 3He Laser#3 Current : 38.1
Polarized 3He Laser#3 Temperature : 11.5
Polarized 3He Laser#4 State : 0
Polarized 3He Laser#4 Current : 37.5
Polarized 3He Laser#4 Temperature : 17.5
Polarized 3He Laser#5 State : 2
Polarized 3He Laser#5 Current : 39.3
Polarized 3He Laser#5 Temperature : 13.1
Polarized 3He Laser#6 State : 2
Polarized 3He Laser#6 Current : 40
Polarized 3He Laser#6 Temperature : 9.2
Polarized 3He Laser#7 State : 2
Polarized 3He Laser#7 Current : 38.8
Polarized 3He Laser#7 Temperature : 9.7
Polarized 3He Coil Current Longitudinal : 0
Polarized 3He Coil Current Transverse : 0