• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name Reitz

    Log entry time 00:02:03 on January 9,2003

    Entry number 91104

    keyword=shift summary

    16:00 continuing data taking in
    He-3 elastic, beam lambda/2 in, target polarisation at 0deg
    16:40 no beam, MCC calls -> 1 hr due to Inj. problems
    17:15 beam available, but work on target
    17:27 back to data taking
    17:37 DAQ trouble, left arm DAQ, ER couldnt start, finally
    reset of all components and kcoda solved problem
    17:54 back to data taking
    Kent is still doing his tests, so there might be a huge charge asymmetry
    18:10 Bob called in, and suggested to use unbuffered mode on right arm
    19:02 finished with this setting
    requested that the beam goes through the compton schicane
    19:50 beam goes through schicane, lets do polarisation measurements
    20:45 two target polarisation measurements are done, target holding field at 180 deg
    and target lambda/2 plate is IN
    20:45 start taking data in beam IN, target 180deg, 3-He elastic
    21:20 CODA on left arm crashed, seems that one ROC hangs, but
    couldnt figure out which (on the components they all look alive)
    rebootet all ROCs and TS, pressed RESET and DOWNLOAD in Coda,
    and it runs again
    21:45 left Q2 quenched
    22:31 back to data taking
    23:16 DAQ problem with left arm, again rebooting ROC14/TS1/ROC3
    solved the problem (probably one would need to reboot only one of them)
    23:50 MCC takes beam away for injector work
    -------------------------------------------------
    beam lambdahalf in / target pol. 0 deg
    20196/1196
    20197/1197
    20198/1198 might have large charge asym. due to tests
    20199/1199 might have large charge asym. due to tests
    20200/1200 huge charge asym
    20201/1201 huge charge asym, left arm crashed
    20202/1202 huge charge asym
    20203/1203 huge charge asym
    20204/1204 huge charge asym, change to unbuffered, high dead time
    20205/1205 huge charge asym, change of prescalers
    20206/1206 huge charge asym
    20207/1207 huge charge asym
    beam lambda/2 IN / target pol. 180deg
    20208/1208/1132 beam position off
    20209/1209/1133 fine
    20210/1210 CODA crashed
    20213/1213/1134 left arm Q2 crashed
    20214/1214/1135
    20215/1215/1136 no beam, empty
    20216/1216/1137
    20217/1217/1138
    20218/1218/1139
    20219/1219/1140