Hall A Experiment #:
01/09/03 0000-0800
Shift Leader: A. Camsonne
Shift Workers: P.Solvignon, R. Feuerbach
0000 | 0100 | 0200 | 0300 | 0400 | 0500 | 0600 | 0700 | Total Time | |
---|---|---|---|---|---|---|---|---|---|
Acceptable Beam in Use | 0.00 | 0.00 | 0.00 | 0.00 | 0.87 | 0.85 | 0.95 | 0.48 | 3.15 |
Beam Available but Not in Use | 0.00 | 0.00 | 0.10 | 0.38 | 0.08 | 0.00 | 0.00 | 0.00 | 0.57 |
Beam Not Available or Unacceptable | 1.00 | 1.00 | 0.90 | 0.62 | 0.05 | 0.15 | 0.05 | 0.52 | 4.28 |
Accelerator Con- figuration Change | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Experiment Ready | 1.00 | 0.42 | 0.00 | 0.00 | 0.92 | 1.00 | 1.00 | 1.00 | 5.33 |
Planned Config- uration Change | 0.00 | 0.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.58 |
Unplanned Experiment Down | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Hall not ready reasons | |||||||||
Target | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 2.00 |
Data Acq | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Other | 0.00 | 0.00 | 0.00 | 0.00 | 0.08 | 0.00 | 0.00 | 0.00 | 0.08 |
HRSL | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HRSR | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
HALL_OFF | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Comments: problems to go at 180 degrees and 270 degrees configurations of the helium 3 target. Lost time trying to go to measurement of Delta asymmetry. G0 started Half wave plate rotating scan at 4AM. Mistuning problem at around 8AM
Data Entry by: A. Camsonne