• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name Antonin Vacheret

    Log entry time 20:12:30 on January 9,2003

    Entry number 91225

    keyword=RHWP scans with hall C

    We are doing a RHWP scan with Hall C.
    the RHWP angle is set at theta=130 degree since 4 pm.
    I have done two runs to check the charge asymmetry :
    run............theta........................Aq......................G0Aq..........
    1177 129.5 ~400 +-30 ~60+-200
    1178 129.5 450 +-25 81 +-200
    1179 129.5 418 +-18 ''
    1180 124.5 -620+-15 -50+-350
    1181 134.5 1370+-12 126.5+-300
    1182 126.5 (6325) -199
    Angle value for zero crossing chosen by hall C for the night is 126.5 (6325). That's consistent with our result ( I found 127.5) so we are all pretty happy.

    Next step is IA scan