Main INDEX
Monthly INDEX
PREV
NEXT
User name R. Michaels
Log entry time 03:30:19 on January10,2003
Entry number 91276
This entry is a followup to: 91269
keyword=Qasy feedback working again
When we started run parity run 1191 the feedback started working again.
It is a mystery why it did nothing for the last half hour of run 1190. I tried
to stop/start the online "pan" analyzer but it didn't revive it.
Also, the initial value of A_q for run 1191 was 592 ppm. The convergence
to zero was slow because I had an artificially large slope (800), so I put this
closer to the true value. I put 150 ppm/V, and A_q converged to zero quickly.