• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name R. Michaels

    Log entry time 03:48:25 on January11,2003

    Entry number 91368

    Followups:

    keyword=Spectrometer and HAPPEX agreement

    It looks like the online packaging of scaler data is working since
    last night (owl 1/10) when I fixed it. Here are some comparisons
    of runs with big charge asymmetries. I noted also the upstream and
    downstream monitors and two gain factors (x3 and x10) are consistent
    among scalers. When the beam is stable the halog gives these values,
    otherwise you can use "qasy" (see ~adaq/qasy/README).

    Run....................HAPPEX...................Left Arm.............Right Arm.
    L / R / P.............(error is ~25 ppm)..........(errors are ~140 ppm)

    20259/1259/1207...... +1330 ...................... +1310 ............ +1264
    20261/1261/1209...... -1500....................... -1140 ............ -1234

    I'll give more comparisons later. RWP scan is in progress now....