    User name Moffit/Vacheret

    Log entry time 17:22:13 on January11,2003

    Entry number 91491

    keyword=IA Scan

    Insertable waveplate was changed during this shift.
    Feedback expert should be paged, whenever this occurs.. This changes the sign and perhaps the magnitude of our IA Slope.

    14:00 Start IA Scan to obtain new slope.

    Run IA Setpoint Q_A
    1226 5 1321

    Problem with Fast Feedback for beam position. MCC takes an access to the injector to fix it. Should be about an hour. Will continue the scan after the access.

    For fun... do a Parity Run to check our pedestals... Run 1227
    Moved signal for x3 Downstream BCM from ADC2_2 to ADC0_0
    Another pedestal run: Run 1228

    Continue IA scan RWP=6725

    Run IA Setpoint Q_A
    1229 1 2336
    1230 5 1556
    1231 9 778


    Unacceptable... because when you change the Insertable Waveplate, the Rotatable Waveplate must also be changed.

    New IA Scan RWP=6435

    Run IA Setpoint Q_A
    1232 9 -387
    1233 5 385
    1234 1 1163
    1235 7 10


    Feel better now, we have a zero charge asymmetry around 7 that's the starting value for the IA. The slope is -193ppm/V

    I put (antonin) back the feedback on after the scan.
    Next step is a halfwave plate scan with hall C during the evening or during the night...