Main INDEX
Monthly INDEX
PREV
NEXT
User name R. Michaels
Log entry time 04:38:58 on January12,2003
Entry number 91546
Followups:
keyword=R-arm dipole update
As the R-arm dipole plummeted to zero current we tried a couple times at
Mark Steven's suggestion to reset it. The supply would "reset" but when we
turned it on there would be a "power supply fault". So we waited for the field
to get to zero which took 2 hours. Then we reset, turned on and tried to ramp up
but at about 24 amps there was a "coil voltage quench". The dipole went to zero.
At present we are slowly bringing up the current by hand. So far so good at 130 A.