• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 04:42:09 on January 23, 2003

    Entry number 93071

    keyword=Start_Run_1503,Run_type=production,beam_energy=5.02,beam_raster=on,comment_text=pol 3He; beam half wave plate IN; 12uA,daq_mode=one HRS daq,kin_name=,leftarm_p=2.957,leftarm_theta=25,rightarm_p=2.575,rightarm_theta=32,target_halfwaveplate=out,target_name=duke,target_polarization=40.8,target_type=Polarized He-3 0deg
    Beginning-of-run EPICS data for Run Number 1503 at Thu Jan 23 04:41:55 EST 2003
    ; RIGHT SPECTROMETER  on adaql2 computer on a-onl account.
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 to measure efficiency
    ; PS1 for the Right spectrometer T1 defined by S1.and.S2
    ; PS2 for the Right spectrometer T2 defined by Cerenkov/S1/S2 majority
    ; PS8 for 1024 Hz pulser (keep this at <= 100)
    ; Trig 9 = 30 Hz, and you cannot prescale it.
     
    ps1=1,ps2=1,ps3=9999,ps4=9999,ps5=65535,ps6=65535,ps7=65535,ps8=65535
    
     
    Right Arm Q1 power supply current :
    Right Arm Q1 momentum : 2.57496
    Right Arm Q1 gauss meter : -0.04784
    Right Arm Q1 power supply polarity :
    Right Arm Q2 power supply current : 1108.25
    Right Arm Q2 momentum : 2.57513
    Right Arm Q2 gauss meter : 0.5819
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 909.473
    Right Arm D1 momentum : 2.575
    Right Arm D1 NMR : 0.955551
    Right Arm Q3 power supply current : 1024.57
    Right Arm Q3 momentum : 2.57488
    Right Arm Q3 gauss meter : 0.4597
    Right Arm Q3 power supply polarity : disabled
    Right Arm Top VDC Current :
    Right Arm Bottom VDC Current :
    Right Arm Top VDC voltage : 3.98877
    Right Arm Bottom VDC voltage : 4.00635
    Average current of the two cavities : 0.0163994
    Current on Unser monitor : -17.4701
    Current on Upstream bcm : 0.0150791
    Current on Downstream bcm : 0.0175872
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    Tiefenbach Hall A energy : 5020
    Tiefenbach Hall C energy : 3027.45
    Delta(E)/E width (MV_AI_DXWID) : 0.398845
    MBSY1c Hall A Beam energy : 5019.53
    MBSY3c Hall C Beam energy : 3036.3
    MBSY1c magnet current (amp) : 209.525
    MBSY1c Bdl : 1.25263e+06
    Arc1 dp/p : -0.00018057
    Arc2 dp/p : 0.000228675
    Right Arm Arm Collimator : 0.863232
    Right LVDT HPM : 3226
    Right LVDT VPM : 3890
    HacR_HPE1313A:0_Ch58 : -0.53418
    HacR_HPE1313A:0_Ch55 : 25.0488
    HacR_HPE1313A:0_Ch54 : -0.73877
    HacR_alignROLL : 0.466989
    HacR_alignPITCH : -0.489172
    HacR_alignHPT : -0
    Right Arm Angle Floor Angle : 32
    Right Arm Angle Vernier : -34
    Right Arm Scattering Angle : 32.001
    IPM1C12.XPOS : 0
    IPM1C12.YPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Survey X offset bpmA : 0
    Survey Y offset bpmA : 0
    Survey X offset bpmB : 0
    Survey Y offset bpmB : 0
    Wien angle : -16.1957
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : -385.6
    Wien field : 10.694
    Laser attenuation Hall A : 100
    Laser power Hall A : 66
    Half-wave plate (off=out) : IN
    rotating waveplate : 6650
    Beam Half-wave plate (off=out) : IN
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : 8 cycles
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : 8 cycles
    G0 Helicity Pattern : Quartet
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : Current is Low
    Arc OTR x-position : -1.7882
    Arc OTR y-position : 0.396298
    Arc OTR x-width : 3.32002
    Arc OTR y-width : 2.0719
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out