Main INDEX
Monthly INDEX
PREV
NEXT
User name averett
Log entry time 00:09:09 on January24,2003
Entry number 93153
keyword=Swing Shift Summary
16:00 Perform NMR measurement, 42.6%, Put target in 180 degree configuration, prepare to continue kinematic setting 5.2.7
16:40 Move to empty reference cell to check beam quality after MCC worked on halo problem today. DAQ troubles on left arm. MCC can't get beam position lock to work. Move back to BeO while they work on it.
17:25 Beam back, DAQ back. Start empty reference cell run.
18:00 Halo looks OK. Begin production running.
18:50 Beam off for RF work.
19:50 Beam back, resume running
20:10 Beam off again for RF problems, calling expert.
23:15 Beam back, check on BeO first, looks good
23:20 NMR measurement. 42.6%
23:40 Resume production running.