User name apar
Log entry time 01:04:27 on February 4, 2003
Entry number 94622
keyword=Start_Parity_Run_1690
Beginning-of-Parity-run EPICS data for Run Number 1690 at Tue Feb 4 01:04:19 EST 2003
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : -16.1957
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -380.29
Wien field : 10.694
Laser attenuation Hall A : 381
Laser power Hall A : 69
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 6435
IA Cell Setpoint Hall A : 4.34893
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.69
Gun2: PC (PITA) NEG : 7.752
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
Parity DAQ Feedback Control(1=on) : 1
IA Feedback Control Hall A : enabled
IA Charge Asymmetry Hall A : 4.83
IA Timestamp Hall A : 1044330771
IA Slope Hall A : 335
LUMI 1 HV - Ch 10 : -1251.4
LUMI 2 HV - Ch 11 : -1250.5
Left Arm Q1 momentum : 2.199
Left Arm Q2 power supply current : 947.04
Left Arm Q2 momentum : 2.19935
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 749.992
Left Arm D1 momentum : 2.199
Left Arm D1 NMR : 0.813663
Left Arm Q3 power supply current : 875.42
Left Arm Q3 momentum : 2.19889
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 2.19902
Right Arm Q1 gauss meter : -0.04089
Right Arm Q2 power supply current : 946.401
Right Arm Q2 momentum : 2.19905
Right Arm Q2 gauss meter : 0.497
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 768.053
Right Arm D1 momentum : 2.199
Right Arm D1 NMR : 0.816022
Right Arm Q3 power supply current : 875.13
Right Arm Q3 momentum : 2.19932
Right Arm Q3 gauss meter : 0.3924
Right Arm Q3 power supply polarity : disabled
Right Arm Top VDC voltage : 3.99365
Right Arm Bottom VDC voltage : 4.00977
Average current of the two cavities : 11.9803
Current on Unser monitor : -3.05265
Current on Upstream bcm : 12.1387
Current on Downstream bcm : 11.8218
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 12.2586
Tiefenbach Hall A energy : 5008.72
Tiefenbach Hall C energy : 3028.39
Delta(E)/E width (MV_AI_DXWID) : 2.29135
MBSY1c Hall A Beam energy : 5019.53
MBSY3c Hall C Beam energy : 3036.3
MBSY1c magnet current (amp) : 209.525
MBSY1c Bdl : 1.25263e+06
Arc1 dp/p : 0.00022564
Arc2 dp/p : 0.000533345
Left Arm Arm Collimator : 0.871191
HacL_HPE1313A:0_Ch58 : -0.170898
HacL_HPE1313A:0_Ch55 : 22.9004
HacL_HPE1313A:0_Ch54 : -0.245605
Right Arm Arm Collimator : 0.863281
Right LVDT HPM : 3216
Right LVDT VPM : 3870
HacR_HPE1313A:0_Ch58 : -0.549316
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 : -0.791016
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 32
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 32.001
IPM1C12.XPOS : 0.00846061
IPM1C12.YPOS : 0.0388895
IPM1H04A.XPOS : 0.92825
IPM1H04A.YPOS : -2.73094
IPM1H04B.XPOS : 0.990605
IPM1H04B.YPOS : -1.98342
Survey X offset bpmA : 0
Survey Y offset bpmA : 0
Survey X offset bpmB : 0
Survey Y offset bpmB : 0
Target OTR x-position : 0.788984
Target OTR y-position : -0.269226
Target OTR x-width : 0.946971
Target OTR y-width : 0.813096
Target OTR data valid flag : No
Target OTR In/Out : MaxPix is Bad
Arc OTR x-position : -10.5973
Arc OTR y-position : 8.6014
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out