Log entry time 23:56:33 on February 4, 2003
Entry number 94845
keyword=Start_Parity_Run_1739
Beginning-of-Parity-run EPICS data for Run Number 1739 at Tue Feb 4 23:56:25 EST 2003
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : -16.1957
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -380.29
Wien field : 10.694
Laser attenuation Hall A : 90
Laser power Hall A : 69
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 6650
IA Cell Setpoint Hall A : 5.74496
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.69
Gun2: PC (PITA) NEG : 7.752
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
Parity DAQ Feedback Control(1=on) : 1
IA Feedback Control Hall A : enabled
IA Charge Asymmetry Hall A : -0.1
IA Timestamp Hall A : 1044420707
IA Slope Hall A : 335
LUMI 1 HV - Ch 10 : -1251.4
LUMI 2 HV - Ch 11 : -1250.5
Left Arm Q1 momentum : 2.199
Left Arm Q2 power supply current : 946.749
Left Arm Q2 momentum : 2.19868
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 749.994
Left Arm D1 momentum : 2.199
Left Arm D1 NMR : 0.81366
Left Arm Q3 power supply current : 875.519
Left Arm Q3 momentum : 2.19914
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 2.19902
Right Arm Q1 gauss meter : -0.0409
Right Arm Q2 power supply current : 946.402
Right Arm Q2 momentum : 2.19906
Right Arm Q2 gauss meter : 0.4971
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 768.05
Right Arm D1 momentum : 2.199
Right Arm D1 NMR : 0.816022
Right Arm Q3 power supply current : 875.037
Right Arm Q3 momentum : 2.19909
Right Arm Q3 gauss meter : 0.3925
Right Arm Q3 power supply polarity : disabled
Right Arm Top VDC voltage : 3.99316
Right Arm Bottom VDC voltage : 4.00977
Average current of the two cavities : 0.834506
Current on Unser monitor : -14.0189
Current on Upstream bcm : 1.13557
Current on Downstream bcm : 1.11146
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 1.06278
Tiefenbach Hall A energy : 5007.24
Tiefenbach Hall C energy : 3028.39
Delta(E)/E width (MV_AI_DXWID) : 7.99179
MBSY1c Hall A Beam energy : 5019.53
MBSY3c Hall C Beam energy : 3036.3
MBSY1c magnet current (amp) : 209.525
MBSY1c Bdl : 1.25263e+06
Arc1 dp/p : 0.000193854
Arc2 dp/p : 0.000369879
Left Arm Arm Collimator : 0.87124
HacL_HPE1313A:0_Ch58 : -0.169922
HacL_HPE1313A:0_Ch55 : 22.9004
HacL_HPE1313A:0_Ch54 : -0.244629
Right Arm Arm Collimator : 0.863281
Right LVDT HPM : 3216
Right LVDT VPM : 3871
HacR_HPE1313A:0_Ch58 : -0.547363
HacR_HPE1313A:0_Ch55 : 22.3145
HacR_HPE1313A:0_Ch54 : -0.790039
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 32
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 32.001
IPM1C12.XPOS : 1.18363
IPM1C12.YPOS : 0.0807391
IPM1H04A.XPOS : 0.846592
IPM1H04A.YPOS : -2.69057
IPM1H04B.XPOS : 0.83117
IPM1H04B.YPOS : -1.98391
Survey X offset bpmA : 0
Survey Y offset bpmA : 0
Survey X offset bpmB : 0
Survey Y offset bpmB : 0
Target OTR x-position : 0.507584
Target OTR y-position : -0.436649
Target OTR x-width : 0.200855
Target OTR y-width : 0.184702
Target OTR data valid flag : No
Target OTR In/Out : MaxPix is Bad
Arc OTR x-position : -10.5973
Arc OTR y-position : 8.6014
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out