• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name Moffit

    Log entry time 18:27:58 on February 6,2003

    Entry number 95107

    This entry is a followup to: 95104

    keyword=Parity Inj DAQ tests.

    Database template file has been fixed.

    Swapped polarity of the cables to the sample and hold cards. They are now looking at the connections that are labelled as negative (e.g. -X+, -X-, -Y+, -Y-).

    Made some runs to see if my changes at the injector bpms worked. Tuned Beam (about 6 uA) was running through injector (up through 5MeV region) at the time.


    Run Result

    5249 Waited for atleast one beam trip.
    Scaler 0- 7: Agree with ADC0_1-4
    Must be very little beam. Gain jumps when beam
    goes off.
    Scaler 8: Gain drops a bit when beam off. Probably ok.
    Scaler 9-11: Same as 0-7.
    Scaler 12-14: No relation to ADCs or other Scaler Channels.
    Maybe MCC is doing something strange.
    Scaler 15: Nothing.

    5250 All scalers (except for 15) seem to be doing the same as the ADCs
    (channel 8 still shows a drop in gain, during a trip).
    Went back to ISB to check on channel 15.

    5151 Flipped v/f switch from nothing to "Ch 16".
    Channel 15 looks fine now.


    Pedestals will need to be calibrated.

    Going home now.