• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name P. Solvignon

    Log entry time 08:11:09 on February 8,2003

    Entry number 95322

    keyword=Shift summary

    EPR-NMR calibration was done while exiting the Hall.

    3:39am --> Hall A is in beam permit and the target is in BeO position and ask for 5uA

    - run #20828/1828: from 3:53am to 4:02am: pointing run

    Kinematics 3.1: E= 3GeV, Theta= 25deg, E'= 1.3338GeV

    Ask for raster off.

    - run #20829/1829: from 4:06am to 4:22am

    4:24am: move target to reference cell position

    ask for raster on and beam position: x=+1.000, y=-2.000

    Stop beam quickly due to the strange behavior of the reference cell.
    Left and Right arm DAQ crashed at the end of the run.
    Reboot all the ROCs and start again CODA.
    Left DAQ was in fact still in genco mode. Doesn't know what it means for the optics run taken under this mode.

    Now target in pol. 3He position.

    Start kin. 3.1.3 (with positions written on the board)

    - run #20831/1831: from 4:57am to 5:26am
    - run #20832/1832: from 5:27am to 6:00am
    - run #20833/1833: from 6:01am to 6:30am
    - run #20834/1834: from 6:31am to 6:41am
    - run #20835/1835: from 6:45am to 7:03am

    MCC is taking the beam away for QE measurement.

    - run #20836/1836: from 7:13am to 7:16am --> enough good events.

    Asked BHWP out (with positions written on the board)

    Start kin. 3.1.4

    - run #20837/1837: from 7:22am to 7:52am
    - run #20838/1838: from 7:53am to ???