User name apar
Log entry time 23:04:45 on February 9, 2003
Entry number 95732
keyword=Start_Parity_Run_1892
Beginning-of-Parity-run EPICS data for Run Number 1892 at Sun Feb 9 23:04:36 EST 2003
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 16.1957
Wien BDL : 369.4
Wien field : 10.694
Laser attenuation Hall A : 414
Laser power Hall A : 69
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 6250
IA Cell Setpoint Hall A : 4.67639
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.704
Gun2: PC (PITA) NEG : 7.538
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
IA Feedback Control Hall A : disabled
IA Charge Asymmetry Hall A : -11.07
IA Timestamp Hall A : 1044849598
IA Slope Hall A : 335
LUMI 1 HV - Ch 10 : -1251.4
LUMI 2 HV - Ch 11 : -1250.5
LUMI 3 HV - Ch 9 : -8.1
Left Arm Q1 momentum : 1.98696
Left Arm Q2 power supply current : 855.478
Left Arm Q2 momentum : 1.98671
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 674.203
Left Arm D1 momentum : 1.98699
Left Arm D1 NMR : 0.735258
Left Arm Q3 power supply current : 790.955
Left Arm Q3 momentum : 1.98673
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 1.98701
Right Arm Q1 gauss meter : -0.03697
Right Arm Q2 power supply current : 855.181
Right Arm Q2 momentum : 1.9871
Right Arm Q2 gauss meter : 0.4492
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 690.274
Right Arm D1 momentum : 1.987
Right Arm D1 NMR : 0.737351
Right Arm Q3 power supply current : 790.628
Right Arm Q3 momentum : 1.98696
Right Arm Q3 gauss meter : 0.3546
Right Arm Q3 power supply polarity : disabled
Right Arm Top VDC voltage : 3.99414
Right Arm Bottom VDC voltage : 4.01074
Average current of the two cavities : 11.911
Current on Unser monitor : -5.02474
Current on Upstream bcm : 11.8492
Current on Downstream bcm : 11.9728
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 12.0316
Tiefenbach Hall A energy : 3028.12
Tiefenbach Hall C energy : 5009.09
Delta(E)/E width (MV_AI_DXWID) : 2.73833
MBSY1c Hall A Beam energy : 3032.98
MBSY3c Hall C Beam energy : 5024.66
MBSY1c magnet current (amp) : 126.273
MBSY1c Bdl : 756885
Arc1 dp/p : 0.000207304
Arc2 dp/p : 0.000731953
Left Arm Arm Collimator : 0.871338
HacL_HPE1313A:0_Ch58 : -0.145996
HacL_HPE1313A:0_Ch55 : 22.998
HacL_HPE1313A:0_Ch54 : -0.182129
Right Arm Arm Collimator : 0.863037
Right LVDT HPM : 3216
Right LVDT VPM : 3868
HacR_HPE1313A:0_Ch58 : -0.536133
HacR_HPE1313A:0_Ch55 : 22.3145
HacR_HPE1313A:0_Ch54 : -0.816895
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 24.5
Right Arm Angle Vernier : 52.8
Right Arm Scattering Angle : 25.0013
IPM1C12.XPOS : -0.00734219
IPM1C12.YPOS : 0.0250432
IPM1H04A.XPOS : 0.990581
IPM1H04A.YPOS : -0.0462788
IPM1H04B.XPOS : 0.948915
IPM1H04B.YPOS : 0.0960595
Survey X offset bpmA : 0
Survey Y offset bpmA : 0
Survey X offset bpmB : 0
Survey Y offset bpmB : 0
Target OTR x-position : 0.690492
Target OTR y-position : 1.69996
Target OTR x-width : 0.960787
Target OTR y-width : 1.32458
Target OTR data valid flag : Yes
Target OTR In/Out :
Arc OTR x-position : -10.5973
Arc OTR y-position : 8.6014
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out