User name apar
Log entry time 16:14:48 on February 10, 2003
Entry number 95901
keyword=Start_Parity_Run_1925
Beginning-of-Parity-run EPICS data for Run Number 1925 at Mon Feb 10 16:14:41 EST 2003
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 16.1957
Wien BDL : 369.4
Wien field : 10.694
Laser attenuation Hall A : 427
Laser power Hall A : 69
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 6250
IA Cell Setpoint Hall A : 4.85182
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 0
Gun2: PC (PITA) NEG : 7.538
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 0
IA Feedback Control Hall A : disabled
IA Charge Asymmetry Hall A : 19.9
IA Timestamp Hall A : 1044908703
IA Slope Hall A : 335
LUMI 1 HV - Ch 10 : -1150.6
LUMI 2 HV - Ch 11 : -1150.4
LUMI 3 HV - Ch 9 : -750.6
Left Arm Q1 momentum : 2.14995
Left Arm Q2 power supply current : 925.5
Left Arm Q2 momentum : 2.14933
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 733.132
Left Arm D1 momentum : 2.15
Left Arm D1 NMR : 0.795543
Left Arm Q3 power supply current : 855.898
Left Arm Q3 momentum : 2.14986
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 2.15009
Right Arm Q1 gauss meter : -0.03998
Right Arm Q2 power supply current : 925.37
Right Arm Q2 momentum : 2.15019
Right Arm Q2 gauss meter : 0.486
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 750.483
Right Arm D1 momentum : 2.15
Right Arm D1 NMR : 0.797837
Right Arm Q3 power supply current : 855.435
Right Arm Q3 momentum : 2.14983
Right Arm Q3 gauss meter : 0.3837
Right Arm Q3 power supply polarity : disabled
Right Arm Top VDC voltage : 3.99365
Right Arm Bottom VDC voltage : 4.01221
Average current of the two cavities : 12.0213
Current on Unser monitor : -3.53008
Current on Upstream bcm : 12.0278
Current on Downstream bcm : 12.1451
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 12.1153
Tiefenbach Hall A energy : 3028.12
Tiefenbach Hall C energy : 5009.09
Delta(E)/E width (MV_AI_DXWID) : 1.83266
MBSY1c Hall A Beam energy : 3032.98
MBSY3c Hall C Beam energy : 5024.66
MBSY1c magnet current (amp) : 126.273
MBSY1c Bdl : 756885
Arc1 dp/p : 0.000217306
Arc2 dp/p : 0.000513731
Left Arm Arm Collimator : 0.871338
HacL_HPE1313A:0_Ch58 : -0.145508
HacL_HPE1313A:0_Ch55 : 23.0957
HacL_HPE1313A:0_Ch54 : -0.182129
Right Arm Arm Collimator : 0.863037
Right LVDT HPM : 3218
Right LVDT VPM : 3871
HacR_HPE1313A:0_Ch58 : -0.536133
HacR_HPE1313A:0_Ch55 : 22.3145
HacR_HPE1313A:0_Ch54 : -0.816895
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 24.5
Right Arm Angle Vernier : 52.8
Right Arm Scattering Angle : 25.0013
IPM1C12.XPOS : -0.00067994
IPM1C12.YPOS : 0.0289532
IPM1H04A.XPOS : 0.987211
IPM1H04A.YPOS : -0.481535
IPM1H04B.XPOS : 0.942204
IPM1H04B.YPOS : 0.0552881
Survey X offset bpmA : 0
Survey Y offset bpmA : 0
Survey X offset bpmB : 0
Survey Y offset bpmB : 0
Target OTR x-position : 0.616894
Target OTR y-position : 1.69944
Target OTR x-width : 0.955515
Target OTR y-width : 1.32336
Target OTR data valid flag : Yes
Target OTR In/Out :
Arc OTR x-position : -10.5973
Arc OTR y-position : 8.6014
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out