Main INDEX
Monthly INDEX
PREV
NEXT
User name apar
Log entry time 22:48:44 on February 10, 2003
Entry number 95979
keyword=Start_Parity_Run_1939
Beginning-of-Parity-run EPICS data for Run Number 1939 at Mon Feb 10 22:48:36 EST 2003
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 16.1957
Wien BDL : 369.4
Wien field : 10.694
Laser attenuation Hall A : 125
Laser power Hall A : 69
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 6200
IA Cell Setpoint Hall A : 5.00084
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.673
Gun2: PC (PITA) NEG : 7.569
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : No Delay
G0 Helicity Pattern Set : Pair
G0 Helicity Random/Toggle Set : Toggle
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : No Delay
G0 Helicity Pattern Read : Pair
G0 Helicity Random/Toggle Read : Toggle
Parity DAQ Feedback Control(1=on) : 1
IA Feedback Control Hall A : enabled
IA Charge Asymmetry Hall A : 2.58
IA Timestamp Hall A : 1044934768
IA Slope Hall A : 335
LUMI 1 HV - Ch 10 : -1151.3
LUMI 2 HV - Ch 11 : -1150.4
LUMI 3 HV - Ch 9 : -750.6
Left Arm Q1 momentum : 2.14995
Left Arm Q2 power supply current : 925.697
Left Arm Q2 momentum : 2.14978
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 733.134
Left Arm D1 momentum : 2.15
Left Arm D1 NMR : 0.795542
Left Arm Q3 power supply current : 856.107
Left Arm Q3 momentum : 2.15038
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 2.15001
Right Arm Q1 gauss meter : -0.03999
Right Arm Q2 power supply current : 925.259
Right Arm Q2 momentum : 2.14993
Right Arm Q2 gauss meter : 0.4859
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 750.482
Right Arm D1 momentum : 2.15
Right Arm D1 NMR : 0.797837
Right Arm Q3 power supply current : 855.542
Right Arm Q3 momentum : 2.1501
Right Arm Q3 gauss meter : 0.3837
Right Arm Q3 power supply polarity : disabled
Right Arm Top VDC voltage : 3.99268
Right Arm Bottom VDC voltage : 4.01025
Average current of the two cavities : 0.017958
Current on Unser monitor : -15.7377
Current on Upstream bcm : 0.0176311
Current on Downstream bcm : 0.0182848
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 1.14777
Tiefenbach Hall A energy : 3028.12
Tiefenbach Hall C energy : 5009.09
Delta(E)/E width (MV_AI_DXWID) : 8.85157
MBSY1c Hall A Beam energy : 3032.98
MBSY3c Hall C Beam energy : 5024.66
MBSY1c magnet current (amp) : 126.273
MBSY1c Bdl : 756885
Arc1 dp/p : 0.000191526
Arc2 dp/p : 0.000548064
Left Arm Arm Collimator : 0.871289
HacL_HPE1313A:0_Ch58 : -0.144531
HacL_HPE1313A:0_Ch55 : 23.1445
HacL_HPE1313A:0_Ch54 : -0.182129
Right Arm Arm Collimator : 0.863037
Right LVDT HPM : 3217
Right LVDT VPM : 3870
HacR_HPE1313A:0_Ch58 : -0.536621
HacR_HPE1313A:0_Ch55 : 22.3145
HacR_HPE1313A:0_Ch54 : -0.817871
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 24.5
Right Arm Angle Vernier : 52.8
Right Arm Scattering Angle : 25.0013
IPM1C12.XPOS : 0.0167147
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : 0
Survey Y offset bpmA : 0
Survey X offset bpmB : 0
Survey Y offset bpmB : 0
Target OTR x-position : -7.9589
Target OTR y-position : 7.73516
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : No
Target OTR In/Out : Current is Low
Arc OTR x-position : -10.5973
Arc OTR y-position : 8.6014
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out