Log entry time 08:04:55 on February 13, 2003
Entry number 96283
keyword=Start_Parity_Run_1977
Beginning-of-Parity-run EPICS data for Run Number 1977 at Thu Feb 13 08:04:49 EST 2003
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : -9.9697
Wien BDL : -236.88
Wien field : 6.5329
Laser attenuation Hall A : 547
Laser power Hall A : 69
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 6250
IA Cell Setpoint Hall A : 4.48615
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.704
Gun2: PC (PITA) NEG : 7.538
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
IA Feedback Control Hall A : enabled
IA Charge Asymmetry Hall A : 4.4
IA Timestamp Hall A : 1045140742
IA Slope Hall A : 335
LUMI 1 HV - Ch 10 : -1251.4
LUMI 2 HV - Ch 11 : -1250.5
LUMI 3 HV - Ch 9 : -800.3
Left Arm Q1 momentum : 2.37888
Left Arm Q2 power supply current : 1024.37
Left Arm Q2 momentum : 2.37894
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 816.857
Left Arm D1 momentum : 2.37899
Left Arm D1 NMR : 0.880407
Left Arm Q3 power supply current : 947.229
Left Arm Q3 momentum : 2.37884
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 2.379
Right Arm Q1 gauss meter : -0.04421
Right Arm Q2 power supply current : 1023.76
Right Arm Q2 momentum : 2.3788
Right Arm Q2 gauss meter : 0.5377
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 836.23
Right Arm D1 momentum : 2.379
Right Arm D1 NMR : 0.882818
Right Arm Q3 power supply current : 946.757
Right Arm Q3 momentum : 2.37933
Right Arm Q3 gauss meter : 0.4247
Right Arm Q3 power supply polarity : disabled
Right Arm Top VDC voltage : 3.99268
Right Arm Bottom VDC voltage : 4.00928
Average current of the two cavities : 14.8868
Current on Unser monitor : -1.62527
Current on Upstream bcm : 14.8252
Current on Downstream bcm : 14.9484
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 14.9812
Tiefenbach Hall A energy : 5008.73
Tiefenbach Hall C energy : 3028.39
Delta(E)/E width (MV_AI_DXWID) : 1.70357
MBSY1c Hall A Beam energy : 5019.53
MBSY3c Hall C Beam energy : 3036.3
MBSY1c magnet current (amp) : 209.525
MBSY1c Bdl : 1.25263e+06
Arc1 dp/p : 0.000154219
Arc2 dp/p : 0.000537829
Left Arm Arm Collimator : 0.871338
HacL_HPE1313A:0_Ch58 : -0.168945
HacL_HPE1313A:0_Ch55 : 22.8516
HacL_HPE1313A:0_Ch54 : -0.245605
Right Arm Arm Collimator : 0.863086
Right LVDT HPM : 3216
Right LVDT VPM : 3871
HacR_HPE1313A:0_Ch58 : -0.54834
HacR_HPE1313A:0_Ch55 : 21.8262
HacR_HPE1313A:0_Ch54 : -0.814453
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 31.5
Right Arm Angle Vernier : 52.5
Right Arm Scattering Angle : 31.9996
IPM1C12.XPOS : 0.0282461
IPM1C12.YPOS : 0.0262198
IPM1H04A.XPOS : 1.06717
IPM1H04A.YPOS : -0.0485937
IPM1H04B.XPOS : 1.01592
IPM1H04B.YPOS : 0.0398315
Survey X offset bpmA : 0
Survey Y offset bpmA : 0
Survey X offset bpmB : 0
Survey Y offset bpmB : 0
Target OTR x-position : 0.883069
Target OTR y-position : 1.74044
Target OTR x-width : 1.35142
Target OTR y-width : 1.16341
Target OTR data valid flag : Yes
Target OTR In/Out :
Arc OTR x-position : -2.26383
Arc OTR y-position : 1.35536
Arc OTR x-width : 3.08447
Arc OTR y-width : 1.28141
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out