Log entry time 13:16:17 on February 13, 2003
Entry number 96299
keyword=Start_Parity_Run_1979
Beginning-of-Parity-run EPICS data for Run Number 1979 at Thu Feb 13 13:16:11 EST 2003
# Timing board information: # Integrate Time = 2.50 ms, Ramp Delay = 0.00 us oversamp 13
Wien angle : -9.9697
Wien BDL : -236.88
Wien field : 6.5329
Laser attenuation Hall A : 175
Laser power Hall A : 69
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 6250
IA Cell Setpoint Hall A : 5.57212
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.704
Gun2: PC (PITA) NEG : 7.538
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
IA Feedback Control Hall A : enabled
IA Charge Asymmetry Hall A : -3.66
IA Timestamp Hall A : 1045144751
IA Slope Hall A : 335
LUMI 1 HV - Ch 10 : -1351.4
LUMI 2 HV - Ch 11 : -1350.5
LUMI 3 HV - Ch 9 : -850.7
Left Arm Q1 momentum : 2.37888
Left Arm Q2 power supply current : 1024.5
Left Arm Q2 momentum : 2.37925
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 816.863
Left Arm D1 momentum : 2.379
Left Arm D1 NMR : 0.880409
Left Arm Q3 power supply current : 947.231
Left Arm Q3 momentum : 2.37927
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 2.379
Right Arm Q1 gauss meter : -0.04423
Right Arm Q2 power supply current : 1023.8
Right Arm Q2 momentum : 2.37891
Right Arm Q2 gauss meter : 0.5378
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 836.222
Right Arm D1 momentum : 2.379
Right Arm D1 NMR : 0.882818
Right Arm Q3 power supply current : 946.457
Right Arm Q3 momentum : 2.37858
Right Arm Q3 gauss meter : 0.4247
Right Arm Q3 power supply polarity : disabled
Right Arm Top VDC voltage : 3.99219
Right Arm Bottom VDC voltage : 4.0083
Average current of the two cavities : 2.45099
Current on Unser monitor : -13.6256
Current on Upstream bcm : 2.44299
Current on Downstream bcm : 2.45898
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 2.43451
Tiefenbach Hall A energy : 5012.41
Tiefenbach Hall C energy : 3028.39
Delta(E)/E width (MV_AI_DXWID) : 7.21985
MBSY1c Hall A Beam energy : 5019.53
MBSY3c Hall C Beam energy : 3036.3
MBSY1c magnet current (amp) : 209.525
MBSY1c Bdl : 1.25263e+06
Arc1 dp/p : 0.000180639
Arc2 dp/p : 0.00135412
Left Arm Arm Collimator : 0.871289
HacL_HPE1313A:0_Ch58 : -0.169922
HacL_HPE1313A:0_Ch55 : 22.7539
HacL_HPE1313A:0_Ch54 : -0.245605
Right Arm Arm Collimator : 0.863037
Right LVDT HPM : 3213
Right LVDT VPM : 3869
HacR_HPE1313A:0_Ch58 : -0.549316
HacR_HPE1313A:0_Ch55 : 21.7285
HacR_HPE1313A:0_Ch54 : -0.815918
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 31.5
Right Arm Angle Vernier : 52.5
Right Arm Scattering Angle : 31.9996
IPM1C12.XPOS : -2.47744
IPM1C12.YPOS : -0.0618093
IPM1H04A.XPOS : 1.00621
IPM1H04A.YPOS : -0.104096
IPM1H04B.XPOS : 0.958758
IPM1H04B.YPOS : -0.0109346
Survey X offset bpmA : 0
Survey Y offset bpmA : 0
Survey X offset bpmB : 0
Survey Y offset bpmB : 0
Target OTR x-position : 0.878388
Target OTR y-position : 1.57442
Target OTR x-width : 1.41393
Target OTR y-width : 1.23253
Target OTR data valid flag : No
Target OTR In/Out : MaxPix is Bad
Arc OTR x-position : -2.21938
Arc OTR y-position : 1.29606
Arc OTR x-width : 3.0846
Arc OTR y-width : 1.28619
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out