User name apar
Log entry time 13:34:42 on February 13, 2003
Entry number 96311
keyword=Start_Parity_Run_1981
Beginning-of-Parity-run EPICS data for Run Number 1981 at Thu Feb 13 13:34:34 EST 2003
# Timing board information: # Integrate Time = 2.50 ms, Ramp Delay = 0.00 us oversamp 13
Wien angle : -9.9697
Wien BDL : -236.88
Wien field : 6.5329
Laser attenuation Hall A : 421
Laser power Hall A : 69
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 6250
IA Cell Setpoint Hall A : 5.57212
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.704
Gun2: PC (PITA) NEG : 7.538
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
IA Feedback Control Hall A : enabled
IA Charge Asymmetry Hall A : -3.66
IA Timestamp Hall A : 1045144751
IA Slope Hall A : 335
LUMI 1 HV - Ch 10 : -1351.4
LUMI 2 HV - Ch 11 : -1350.5
LUMI 3 HV - Ch 9 : -850.7
Left Arm Q1 momentum : 2.37888
Left Arm Q2 power supply current : 1024.52
Left Arm Q2 momentum : 2.37933
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 816.862
Left Arm D1 momentum : 2.379
Left Arm D1 NMR : 0.88041
Left Arm Q3 power supply current : 947.022
Left Arm Q3 momentum : 2.37874
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 2.379
Right Arm Q1 gauss meter : -0.04422
Right Arm Q2 power supply current : 1023.75
Right Arm Q2 momentum : 2.37877
Right Arm Q2 gauss meter : 0.5378
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 836.222
Right Arm D1 momentum : 2.379
Right Arm D1 NMR : 0.882817
Right Arm Q3 power supply current : 946.414
Right Arm Q3 momentum : 2.37847
Right Arm Q3 gauss meter : 0.4247
Right Arm Q3 power supply polarity : disabled
Right Arm Top VDC voltage : 3.99365
Right Arm Bottom VDC voltage : 4.00488
Average current of the two cavities : 11.9975
Current on Unser monitor : -3.67273
Current on Upstream bcm : 11.9599
Current on Downstream bcm : 12.0391
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 12.1294
Tiefenbach Hall A energy : 5008.68
Tiefenbach Hall C energy : 3028.39
Delta(E)/E width (MV_AI_DXWID) : 2.1972
MBSY1c Hall A Beam energy : 5019.53
MBSY3c Hall C Beam energy : 3036.3
MBSY1c magnet current (amp) : 209.525
MBSY1c Bdl : 1.25263e+06
Arc1 dp/p : 0.000156979
Arc2 dp/p : 0.000584876
Left Arm Arm Collimator : 0.871338
HacL_HPE1313A:0_Ch58 : -0.170898
HacL_HPE1313A:0_Ch55 : 22.7539
HacL_HPE1313A:0_Ch54 : -0.244629
Right Arm Arm Collimator : 0.863037
Right LVDT HPM : 3212
Right LVDT VPM : 3869
HacR_HPE1313A:0_Ch58 : -0.549316
HacR_HPE1313A:0_Ch55 : 21.6309
HacR_HPE1313A:0_Ch54 : -0.816895
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 31.5
Right Arm Angle Vernier : 52.5
Right Arm Scattering Angle : 31.9996
IPM1C12.XPOS : 0.0100147
IPM1C12.YPOS : 0.0175362
IPM1H04A.XPOS : 1.05288
IPM1H04A.YPOS : -0.0511857
IPM1H04B.XPOS : 1.00146
IPM1H04B.YPOS : 0.0261234
Survey X offset bpmA : 0
Survey Y offset bpmA : 0
Survey X offset bpmB : 0
Survey Y offset bpmB : 0
Target OTR x-position : 0.643136
Target OTR y-position : 1.71609
Target OTR x-width : 0.861338
Target OTR y-width : 0.751191
Target OTR data valid flag : No
Target OTR In/Out : MaxPix is Bad
Arc OTR x-position : -2.22237
Arc OTR y-position : 1.29228
Arc OTR x-width : 3.10593
Arc OTR y-width : 1.30689
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out