Log entry time 15:26:09 on February 13, 2003
Entry number 96345
keyword=Start_Parity_Run_1987
Beginning-of-Parity-run EPICS data for Run Number 1987 at Thu Feb 13 15:26:02 EST 2003
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : -9.9697
Wien BDL : -236.88
Wien field : 6.5329
Laser attenuation Hall A : 214
Laser power Hall A : 69
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 6250
IA Cell Setpoint Hall A : 5.46072
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.704
Gun2: PC (PITA) NEG : 7.538
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
IA Feedback Control Hall A : enabled
IA Charge Asymmetry Hall A : -2.24
IA Timestamp Hall A : 1045167209
IA Slope Hall A : 335
LUMI 1 HV - Ch 10 : -1251.4
LUMI 2 HV - Ch 11 : -1250.5
LUMI 3 HV - Ch 9 : -800.3
Left Arm Q1 momentum : 2.37888
Left Arm Q2 power supply current : 1024.28
Left Arm Q2 momentum : 2.37873
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 816.866
Left Arm D1 momentum : 2.379
Left Arm D1 NMR : 0.88041
Left Arm Q3 power supply current : 947.005
Left Arm Q3 momentum : 2.3787
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 2.379
Right Arm Q1 gauss meter : -0.04425
Right Arm Q2 power supply current : 1023.8
Right Arm Q2 momentum : 2.37889
Right Arm Q2 gauss meter : 0.5379
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 836.213
Right Arm D1 momentum : 2.37899
Right Arm D1 NMR : 0.882816
Right Arm Q3 power supply current : 946.497
Right Arm Q3 momentum : 2.37868
Right Arm Q3 gauss meter : 0.4247
Right Arm Q3 power supply polarity : disabled
Right Arm Top VDC voltage : 3.99414
Right Arm Bottom VDC voltage : 4.00879
Average current of the two cavities : 4.65854
Current on Unser monitor : -10.9284
Current on Upstream bcm : 4.64937
Current on Downstream bcm : 5.68202
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 4.68457
Tiefenbach Hall A energy : 5009.66
Tiefenbach Hall C energy : 3028.39
Delta(E)/E width (MV_AI_DXWID) : 2.76627
MBSY1c Hall A Beam energy : 5019.53
MBSY3c Hall C Beam energy : 3036.3
MBSY1c magnet current (amp) : 209.525
MBSY1c Bdl : 1.25263e+06
Arc1 dp/p : 0.000415315
Arc2 dp/p : 0.00074988
Left Arm Arm Collimator : 0.87124
HacL_HPE1313A:0_Ch58 : -0.170898
HacL_HPE1313A:0_Ch55 : 22.6074
HacL_HPE1313A:0_Ch54 : -0.245605
Right Arm Arm Collimator : 0.863086
Right LVDT HPM : 3210
Right LVDT VPM : 3868
HacR_HPE1313A:0_Ch58 : -0.55127
HacR_HPE1313A:0_Ch55 : 21.5332
HacR_HPE1313A:0_Ch54 : -0.818848
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 31.5
Right Arm Angle Vernier : 52.5
Right Arm Scattering Angle : 31.9996
IPM1C12.XPOS : -0.136646
IPM1C12.YPOS : 0.0561878
IPM1H04A.XPOS : 1.09836
IPM1H04A.YPOS : -0.0723997
IPM1H04B.XPOS : 1.058
IPM1H04B.YPOS : 0.0168169
Survey X offset bpmA : 0
Survey Y offset bpmA : 0
Survey X offset bpmB : 0
Survey Y offset bpmB : 0
Target OTR x-position : 0.852415
Target OTR y-position : 1.70351
Target OTR x-width : 1.1102
Target OTR y-width : 0.948245
Target OTR data valid flag : Yes
Target OTR In/Out :
Arc OTR x-position : -2.23815
Arc OTR y-position : 1.29558
Arc OTR x-width : 3.08427
Arc OTR y-width : 1.322
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out