Main INDEX
Monthly INDEX
PREV
NEXT
User name apar
Log entry time 02:11:29 on February 14, 2003
Entry number 96430
keyword=Start_Parity_Run_2005
Beginning-of-Parity-run EPICS data for Run Number 2005 at Fri Feb 14 02:11:23 EST 2003
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : -9.19573
Wien BDL : -218.398
Wien field : 6.0156
Laser attenuation Hall A : 150
Laser power Hall A : 69
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 6250
IA Cell Setpoint Hall A : 5.53728
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.704
Gun2: PC (PITA) NEG : 7.538
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
IA Feedback Control Hall A : enabled
IA Charge Asymmetry Hall A : -0.34
IA Timestamp Hall A : 1045195497
IA Slope Hall A : 335
LUMI 1 HV - Ch 10 : -1251.4
LUMI 2 HV - Ch 11 : -1250.5
LUMI 3 HV - Ch 9 : -800.3
Left Arm Q1 momentum : 2.00002
Left Arm Q2 power supply current : 861.207
Left Arm Q2 momentum : 2.00002
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 678.276
Left Arm D1 momentum : 2
Left Arm D1 NMR : 0.740069
Left Arm Q3 power supply current : 796.377
Left Arm Q3 momentum : 2.00035
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 2.379
Right Arm Q1 gauss meter : -0.04424
Right Arm Q2 power supply current : 1023.73
Right Arm Q2 momentum : 2.37874
Right Arm Q2 gauss meter : 0.5378
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 836.232
Right Arm D1 momentum : 2.379
Right Arm D1 NMR : 0.882818
Right Arm Q3 power supply current : 946.53
Right Arm Q3 momentum : 2.37876
Right Arm Q3 gauss meter : 0.4248
Right Arm Q3 power supply polarity : disabled
Right Arm Top VDC voltage : 3.99121
Right Arm Bottom VDC voltage : 4.00977
Average current of the two cavities : 1.89793
Current on Unser monitor : -13.8503
Current on Upstream bcm : 1.88758
Current on Downstream bcm : 1.90827
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 1.90304
Tiefenbach Hall A energy : 5007.47
Tiefenbach Hall C energy : 3028.39
Delta(E)/E width (MV_AI_DXWID) : 6.8339
MBSY1c Hall A Beam energy : 5019.53
MBSY3c Hall C Beam energy : 3036.3
MBSY1c magnet current (amp) : 209.525
MBSY1c Bdl : 1.25263e+06
Arc1 dp/p : 0.000189574
Arc2 dp/p : 0.000340733
Left Arm Arm Collimator : 0.871289
HacL_HPE1313A:0_Ch58 : -0.199707
HacL_HPE1313A:0_Ch55 : 23.1445
HacL_HPE1313A:0_Ch54 : 0.0800781
Right Arm Arm Collimator : 0.863037
Right LVDT HPM : 3215
Right LVDT VPM : 3873
HacR_HPE1313A:0_Ch58 : -0.543457
HacR_HPE1313A:0_Ch55 : 22.1191
HacR_HPE1313A:0_Ch54 : -0.881836
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 47.5
Right Arm Angle Vernier : -7
Right Arm Scattering Angle : 47.6567
IPM1C12.XPOS : 1.24477
IPM1C12.YPOS : -0.00219725
IPM1H04A.XPOS : 0.934484
IPM1H04A.YPOS : -0.0475185
IPM1H04B.XPOS : 1.0184
IPM1H04B.YPOS : 0.0257067
Survey X offset bpmA : 0
Survey Y offset bpmA : 0
Survey X offset bpmB : 0
Survey Y offset bpmB : 0
Target OTR x-position : 0.730429
Target OTR y-position : 1.14942
Target OTR x-width : 1.12854
Target OTR y-width : 1.27836
Target OTR data valid flag : No
Target OTR In/Out : MaxPix is Bad
Arc OTR x-position : -2.24923
Arc OTR y-position : 1.3449
Arc OTR x-width : 3.09157
Arc OTR y-width : 1.2908
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out