• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 15:19:00 on April 12, 2003

    Entry number 97654

    keyword=Start_Run_1141,Run_type=cosmics,beam_energy=5.008,beam_raster=on,comment_text=tests,daq_mode=one HRS daq,kin_name=,leftarm_p=2.0,leftarm_theta=14.997,rightarm_p=2379,rightarm_theta=47.657,target_halfwaveplate=out,target_name=exodus,target_polarization=39.2,target_type=Reference Cell He3
    Beginning-of-run EPICS data for Run Number 1141 at Sat Apr 12 15:18:45 EDT 2003
    ; RIGHT SPECTROMETER  on adaql2 computer on a-onl account.
    ; Prescale factors (integer), downloaded each run at prestart.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 to measure efficiency
    ; PS1 for the Right spectrometer T1 defined by S1.and.S2
    ; PS2 for the Right spectrometer T2 defined by Cerenkov/S1/S2 majority
    ; PS8 for 1024 Hz pulser (keep this at <= 100)
    ; Trig 9 = 30 Hz, and you cannot prescale it.
     
    ps1=1,ps2=10,ps3=9999,ps4=9999,ps5=65535,ps6=65535,ps7=65535,ps8=65535
                                                             
     
    Right Arm Q1 power supply current :
    Right Arm Q1 momentum : 0.132463
    Right Arm Q1 gauss meter : -0.0025672
    Right Arm Q1 power supply polarity :
    Right Arm Q2 power supply current : 0.332478
    Right Arm Q2 momentum : 0.000772545
    Right Arm Q2 gauss meter : 0.0001608
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 52.1204
    Right Arm D1 momentum : 0
    Right Arm D1 NMR : 0.340256
    Right Arm Q3 power supply current : -0.000206885
    Right Arm Q3 momentum : -5.19931e-07
    Right Arm Q3 gauss meter : -0.0001926
    Right Arm Q3 power supply polarity : enabled
    Right Arm Top VDC Current :
    Right Arm Bottom VDC Current :
    Right Arm Top VDC voltage : -0.00488281
    Right Arm Bottom VDC voltage : -0.0161133
    Average current of the two cavities : 0.0176261
    Current on Unser monitor : -15.4169
    Current on Upstream bcm : 0.0200274
    Current on Downstream bcm : 0.0152248
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143715
    Tiefenbach Hall A energy : 5008.97
    Tiefenbach Hall C energy : 2237.06
    Delta(E)/E width (MV_AI_DXWID) : 0
    MBSY1c Hall A Beam energy : 5019.53
    MBSY3c Hall C Beam energy : 2242.19
    MBSY1c magnet current (amp) : 0
    MBSY1c Bdl : 1.25263e+06
    Arc1 dp/p : 0
    Arc2 dp/p : 0
    Right Arm Arm Collimator : -0.000390625
    Right LVDT HPM : 3214
    Right LVDT VPM : 3870
    HacR_HPE1313A:0_Ch58 : -0.564941
    HacR_HPE1313A:0_Ch55 : 22.1191
    HacR_HPE1313A:0_Ch54 : -0.842773
    HacR_alignROLL : 0.466989
    HacR_alignPITCH : -0.489172
    HacR_alignHPT : -0
    Right Arm Angle Floor Angle : 47.5
    Right Arm Angle Vernier : -7
    Right Arm Scattering Angle : 47.6567
    IPM1C12.XPOS : 0
    IPM1C12.YPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle : 44.8063
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1028.6
    Wien field : 29.811
    Laser attenuation Hall A : 300
    Laser power Hall A : 69
    Half-wave plate (off=out) : OUT
    rotating waveplate : 6250
    Beam Half-wave plate (off=out) : OUT
    G0 Helicity Settle Set : 500 usec
    G0 Helicity Delay Set : 8 cycles
    G0 Helicity Pattern Set : Quartet
    G0 Helicity Settle Read : 500 usec
    G0 Helicity Delay Read : 8 cycles
    G0 Helicity Pattern : Quartet
    Target OTR x-position : -0.154994
    Target OTR y-position : -2.41136
    Target OTR x-width : 2.37011
    Target OTR y-width : 2.8715
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    Arc OTR x-position : -2.06489
    Arc OTR y-position : -0.139918
    Arc OTR x-width : 2.96785
    Arc OTR y-width : 3.01999
    Arc OTR data valid flag : !!WARNING!! The executable "caRepeater" couldnt be located because of errno = "No such file or directory" You may need to modify your PATH environment variable. Creating CA repeater with fork() system call. Repeater will inherit parents process name and resources. Duplicate resource consumption may occur.
    Arc OTR In/Out : OTR is Out