Log entry time 17:20:02 on April 15, 2003
Entry number 97683
keyword=Start_Parity_Run_2636__CODA_Config=GDH
Beginning-of-Parity-run EPICS data for Run Number 2636 at Tue Apr 15 17:19:52 EDT 2003
CODA Configuration: GDH
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Wien angle : 44.8063
Wien BDL : 1028.6
Wien field : 29.811
Laser attenuation Hall A : 300
Laser power Hall A : 69
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 6250
IA Cell Setpoint Hall A : 5.53728
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.22359
Gun2: PC (PITA) NEG : 7.457
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set :
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 0
IA Feedback Control Hall A : disabled
IA Charge Asymmetry Hall A : -0.34
IA Timestamp Hall A : 1045195497
IA Slope Hall A : 335
LUMI 1 HV - Ch 10 :
LUMI 2 HV - Ch 11 :
LUMI 3 HV - Ch 9 :
Left Arm Q1 momentum : 0.132251
Left Arm Q2 power supply current : 100.061
Left Arm Q2 momentum : 0.232376
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 0.137917
Left Arm D1 momentum : 0
Left Arm D1 NMR : 0.41838
Left Arm Q3 power supply current : 99.9864
Left Arm Q3 momentum : 0.251147
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.132392
Right Arm Q1 gauss meter : -0.0025476
Right Arm Q2 power supply current : 39.6295
Right Arm Q2 momentum : 0.0920829
Right Arm Q2 gauss meter : 0.020737
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 52.1193
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.296642
Right Arm Q3 power supply current : -0.000357347
Right Arm Q3 momentum : -8.98062e-07
Right Arm Q3 gauss meter : -0.0001964
Right Arm Q3 power supply polarity : enabled
Right Arm Top VDC voltage : -0.00488281
Right Arm Bottom VDC voltage : -0.0151367
Average current of the two cavities : 0.0176012
Current on Unser monitor : -14.835
Current on Upstream bcm : 0.019776
Current on Downstream bcm : 0.0154263
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143715
Tiefenbach Hall A energy : 5008.97
Tiefenbach Hall C energy : 2237.2
Delta(E)/E width (MV_AI_DXWID) : 1.25906
MBSY1c Hall A Beam energy : 5019.53
MBSY3c Hall C Beam energy : 2242.19
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 1.25263e+06
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Arm Collimator : 0.0652832
HacL_HPE1313A:0_Ch58 : -0.153809
HacL_HPE1313A:0_Ch55 : 22.5586
HacL_HPE1313A:0_Ch54 : -0.0737305
Right Arm Arm Collimator : -0.000341797
Right LVDT HPM : 3213
Right LVDT VPM : 3870
HacR_HPE1313A:0_Ch58 : -0.529785
HacR_HPE1313A:0_Ch55 : 21.8262
HacR_HPE1313A:0_Ch54 : -0.840332
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 18
Right Arm Angle Vernier : -34.2
Right Arm Scattering Angle : 17.9999
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Target OTR x-position : 0.440137
Target OTR y-position : -1.06134
Target OTR x-width : 2.49499
Target OTR y-width : 2.79797
Target OTR data valid flag : No
Target OTR In/Out : OTR is Out
Arc OTR x-position : -2.05768
Arc OTR y-position : -0.139822
Arc OTR x-width : 2.96589
Arc OTR y-width : 3.03918
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out